20 / 23 page ![]() Application EMC immunity AN4075 20/23 Doc ID 022954 Rev 1 4.3.3 Test setup The test was executed on the IO-Link bus lines (L+, C/Q and I/Q vs. earth reference). Tests were made on the output lines vs. earth - common mode (CM), as well as on output lines vs. L- (GND) - in differential mode. The earth reference is coupled by 2 x 4.7 nF/3 kV capacitors (C1, C14) with VCC and GND. The length of the cables was minimized. The surge pulse was coupled with a coupling network of 42 Ω/0.5 μF. After every surge sequence, the power supply current and C/Q, I/Q current sink values were measured and compared to their initial state and the functionality of the receiver and driver paths (functionality of the output switches) was checked. 4.3.4 Test results Table 6. Application surge immunity - common mode Surge test signal amplitude, test result at polarity (+ / -) Applied to 500 V 1 kV 1.5 kV 2 kV 2.5 kV L+ OFF - / - A(1) / A(1) 1. The values of the L6360 internal registers did not change. A(1) / A(1) A(1) / A(1) A(1) / A(1) L+ ON A(1) / A(1) A(1) / A(1) A(1) / A(1) A(1) / A(1) A(1) / A(1) C/Q LS ON A(1) / A(1) A(1) / A(1) A(1) / A(1) A(1) / A(1) A(1) / A(1) C/Q HS ON A(1) / A(1) A(1) / A(1) A(1) / A(1) A(1) / A(1) A(1) / A(1) C/Q Rx mode A(1) / A(1) A(1) / A(1) A(1) / A(1) A(1) / A(1) A(1) / A(1) I/Q - / - A(1) / A(1) A(1) / A(1) A(1) / A(1) A(1) / A(1) Table 7. Application surge immunity - differential mode Surge test signal amplitude, test result at polarity (+ / -) Applied to 500 V 1 kV 1.5 kV 2 kV 2.5 kV L+ OFF A(1) / A(1) 1. The values of the L6360 internal registers did not change. A(1)/ A(1) - / - - / - - / - L+ ON A(1)/ B(2) 2. The L6360 registers were reset, IRQ signal is activated. B(2) / B(2) - / - - / - - / - C/Q LS ON A(1)/ A(1) A(1) / B(2) - / - - / - - / - C/Q HS ON A(1)/ A(1) A(1) / B(2) - / - - / - - / - C/Q Rx mode A(1) / B(2) B(2) / B(2) - / - - / - - / - I/Q A(1)/ A(1) A(1)/ A(1) - / - - / - - / - |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |