13 / 35 page ![]() 13/35 AN1946 Advantages With the classical method, BEMF sampling is done during the PWM “ON” state allowing up to a maximum PWM duty cycle (100%). Drawbacks Due to the voltage divider being used to sense BEMF, this method is less sensitive that the ST method. This sampling method is dependent on the motor speed because the different net- works are influenced by BEMF levels and components are to be dimensioned according to the nominal operation point of the motor. 4.2 PRACTICAL IMPLEMENTATION OF SAMPLING DURING PWM ON The starter kit board is delivered with a daughter board allowing classical sampling method use. Figure 12 gives an example of network use to implement the classical method with an analog filter. Figure 12. Classical method of implementation with daughter board. R5 R3 R1 R10 C1 C2 C3 C4 MCVREF MCIA ST7FMC Three Phase Power Converter V U W VDC 6_MCOx Motor MCIB MCIC |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|