| Electronic Components Datasheet Search |
|
PAS395 Datasheet(PDF) 5 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
PAS395 Datasheet(HTML) 5 Page - PULS GmbH |
|
5 / 14 page ![]() This document is proprietary. Any dispatch or disclosure of content is authorized only after written authorization by PULS GmbH. All parameters are specified at 400V, 2.5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. Specification: SP-PAS395 Rev: 3.1 Date: 2013/01/19 5-14 Output Ripple-Voltage: Without connected capacitor bank: typ. 6Vpp , max. 10Vpp With connected capacitor bank: negligible Output Current Ripple: During charging: typ. 150mApp , max. 300mApp Output Return Current: Max. 1mA (discharge current when charger is not working) Procedure for Setting the End-of-Charge” Voltage: Setting the end-of-charge voltage shall be done in a laboratory. The output shall be open (not loaded, no capacitor needed). The output voltage (end-of-charge voltage) shall be measured with a digital voltmeter. Factory setting of the end-of-charge voltage is 410Vdc and the OVP level is 10V higher. Changing of these values can be done according to the following examples: Example 1: Setting the end-of-charge voltage to 420V and OVP to 430V Step 1: Push the “OVP disable / enable” button to disable the OVP. The red LED will start and keep flashing for two minutes. For this period of time the end-of-charge voltage can be set without triggering the OVP. Ensure that the unit is not in OVP mode before starting with step 1. Step 2: Set the end-of-charge voltage to 420V Step 3: Push the “OVP disable / enable” button again to set the OVP voltage 10V higher than the end-of-charge voltage(= 430Vdc). Red LED will go off. done Example 2: Setting the end-of-charge voltage to 430V and OVP to 450V Step 1: Push the “OVP disable / enable” button to disable the OVP. The red LED will start and keep flashing for two minutes. For this period of time the end-of-charge voltage can be set without triggering the OVP. Step 2: Set the end-of-charge voltage to 440V Step 3: Push the “OVP disable / enable” button again to set the OVP voltage 10V higher than the end-of-charge voltage(= 450Vdc). Red LED will go off. Step 4: Set the end-of-charge voltage to 430V (without pushing the button) done |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |