33 / 48 page ![]() LPS35HW Register description DocID029129 Rev 1 33/48 8.5 CTRL_REG1 (10h) Control register 1 Table 18: CTRL_REG1 (10h) register 7 6 5 4 3 2 1 0 0a ODR2 ODR1 ODR0 EN_LPFP LPFP_CFG BDU SIM ODR [2:0] Output data rate selection. Default value: 000 Refer to Table 19: "Output data rate bit configurations". EN_LPFP Enable low-pass filter on pressure data. Default value: 0 (0: Low-pass filter disabled; 1: Low-pass filter enabled) LPFP_CFG LPF_CFG: Low-pass configuration register. Default value:0 Refer to Table 20: "Low- pass filter configurations". BDUb Block data update. Default value: 0 (0: continuous update; 1:output registers not updated until MSB and LSB have been read) SIM SPI Serial Interface Mode selection. Default value: 0(0: 4-wire interface; 1: 3-wire interface) Table 19: Output data rate bit configurations ODR2 ODR1 ODR0 Pressure (Hz) Temperature (Hz) 0 0 0 Power down / One shot mode enabled 0 0 1 1 Hz 1 Hz 0 1 0 10 Hz 10 Hz 0 1 1 25 Hz 25 Hz 1 0 0 50 Hz 50 Hz 1 0 1 75 Hz 75 Hz When ODR bits are set to '000' the device is in Power down mode. When the device is in power-down mode, almost all internal blocks of the device are switched off to minimize power consumption. I2C interface is still active to allow communication with the device. The configuration registers content is preserved and output data registers are not updated, therefore keeping the last data sampled in memory before going into power- down mode. If ONE_SHOT bit in CTRL_REG2(11h) is set to '1', One-shot mode is triggered and a new acquisition starts when it is required. This enabling is effective only if the device was previously in power-down mode (ODR bits set to '000'). Once the acquisition is completed and the output registers updated, the device automatically enters in power down mode. ONE_SHOT bit self-clears itself. When ODR bits are set to a value different than '000', the device is in Continuous mode and automatically acquires a set of data (pressure and temperature) at the frequency selected through ODR[2,0] bits. a This bit must be set to ‘0’ for proper operation of the device b To guarantee the correct behavior of BDU feature, th PRESS_OUT_H (2Ah) must be the last address read. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |