| Electronic Components Datasheet Search |
|
RT9750WSC Datasheet(PDF) 10 Page - Richtek Technology Corporation |
|
|
|||||||||||||||||||||||||||||
RT9750WSC Datasheet(HTML) 10 Page - Richtek Technology Corporation |
|
10 / 30 page ![]() RT9750 10 DS9750-01 June 2017 www.richtek.com © Copyright 2017 Richtek Technology Corporation. All rights reserved. is a registered trademark of Richtek Technology Corporation. Application Information Device Power On The internal bias circuit (VDDA) are powered from higher of two voltages between VBUS and VOUT. The device will powered on when the VDDA is higher than VDDA UVLO threshold and EN pin is higher than VIH_EN. In VBUS > VDDA UVLO & EN pin from low logic to high logic condition, the device need maximum 500 μs turn on delay time after EN pin set to high logic. Smart Load Switch The RT9750 is a 8m Ω RON and loading can up to 6-A smart load switch battery charger. The load switch can be controlled by the host via I2C. The load switch can be turn on by set CHG_EN bit to “1” (0x06 bit4) if no protection event happened (Please check 0X03 & 0X04). The load switch can be turn off by set CHG_EN bit to “0” or pull EN pin to low. If the protection event happen the load switch will be turn off automatically and set CHG_EN bit to “0” The smart load switch also implement soft-on & soft off to function minimize the inrush current and voltage spike. 8-Channel 12-bit Analog to Digital Converter The device integrate 8-Cannel 12 bit ADC function, user can monitor voltage of VBUS, VOUT, VDROP (voltage different between VBUS and VOUT), and VBAT. The user also can monitor the internal junction temperature, battery temperature (by external resistor divider and NTC thermistor), and VBUS temperature (by external resistor divider and NTC thermistor). The ADC function also provide IBUS information for user to monitor. User can set ADC_EN (0x07 bit3) bit to enable or disable ADC conversion. User also can enable or disable ADC channels respective by using register 0x07 and 0x08. The ADC has two conversion rate 1- shot mode and continuous mode. User can select the mode by ADC_RATE bit (0X07 bit2). 1. 1-shot mode In this mode, user need to set ADC_EN bit to 1 to start ADC conversion. The ADC_EN bit will change to 0 automatically after ADC start conversion. After the ADC conversion complete, the ADC_DONE bit (0x04 bit6) will change to 1 and INT pin will pull low if the ADC_DONE_MASK bit is no mask. The typical conversion time of one channel is 100 μs (16 averages). 2. Continuous mode In continuous mode, ADC conversion continuously if user set ADC_EN bit to 1 and ADC stop conversion if user set ADC_EN bit to 0. User can set the ADC_AVG_EN bit to enable or disable ADC measurement averaging function in both 1-shot mode and continuous mode. If ADC_AVG_EN = 0 the ADC is instantaneous measurement. IfADC_AVG_EN= 1 the ADC is averaging measurement and user can set the number of samples by ADC_SAMPLES bit. Linear Regulation Mode (LDO) The load switch implement LDO mode to regulate VOUT voltage, battery voltage and input current. If an event that VOUT_REG, VBAT_REG or IBUS_REG threshold is exceeded, the load switch act as LDO and will regulate VOUT, VBAT, IBUS (depending upon which threshold is exceeded). These regulations threshold can be selected by I2C. Protection Features The load switch implement 5 way hardware protection and 2 temperature protection as below. All these protection functions have IRQ and active with INT pin to inform host to monitor which protection is active. 1. VBUS Over-Voltage Protection (VBUS_OVP) When VBUS_OVP event is happened the device will turn off load switch and the CHG_EN bit will be set to 0. User can enable or disable this protection function by I2C 0x06 bit 7. The protection threshold and deglitch time also can be selected by I2C (Protection threshold is 0x0A, deglitch time is 0x09 bit0). 2. VBUS Over-Temperature Protection (TSVBUS_OTP) As below picture, user need to place an external NTC voltage dived circuit at TSBUS pin. When the voltage of TSBUS pin is over the threshold, the device will turn off load switch and set CHG_EN bit to 0. User can enable or |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |