| Electronic Components Datasheet Search |
|
AS89010 Datasheet(PDF) 22 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS89010 Datasheet(HTML) 22 Page - ams AG |
|
22 / 42 page ![]() ams.com db12348e_V3.11_preliminary_2017-07-06 Page 21 of 41 AS89010 V3.11 OPERATIONAL STATE REGISTER OSR NAME VALUE [b] AFFECTED OPERATIONAL STATE Operational State 01020 operational state: configuration 011 operational state: measurement 1XX reserved DOS switches the operational state of the device between configuration and measurement. The configuration state enables the access to the register bank (Table 7). No measurement takes place. The measurements can only be performed in the measurement state and any access to the control register bank (except OSR) is not permitted. The control register would be reset to their default values each time the operational state is switched back to the configuration state. The start of the measurement is controlled by the value of the SS bit. These signals are evaluated only in the measurement state and only in the CONT and CMD Mode (refer to chapter 5.1). The Power down mode is controlled by the PD value. The Power down takes effect in both operational states. If the PD is active in the measurement state, the Power down would be performed only during the breaks between two consequent conversions. 6.2.1 API Generation Register – AGEN The value of this read only register indicates the generation of the Control Register Bank. The value of the register changes whenever any formal modification is introduced to the Control Register Bank. This case indicates that the Application Programming Interface (API) has been changed. Table 9: AGEN register - Address 02h AGEN NAME VALUE [b] DESCRIPTION bit 7 to 4 DEVID 0010 Device ID number; the value 0010b is reserved for MCDC devices bit 3 to 0 MUT 0000 Mutation number of Control Register Bank 6.2.2 Configuration Register – CREGL and CREGH The configuration register CREGL mainly serves to define full-scale-range, sensitivity and conversion time of the device. Table 10: CREGL register - Address 06h CREGL NAME VALUE [b] AFFECTED CONFIGURATION 0 input current direction out of the IN0-IN4 pins (the cathodes of the photodiode connected to the input pins) 122 input current direction into the IN0-IN4 pin (the anodes of the photodiodes connected to the input pins) ADC Reference Current IREF ADC LSB Current (TINT=1024 ms) 000 20 nA 20 fA 001 80 nA 80 fA 010 320 nA 320 fA 22 Default after power-on-reset and state change from measurement to configuration. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |