2 / 10 page ![]() Solid State SP2T Switch USB USB-1SP2T-34 www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com PAGE 2 OF 10 ELECTRICAL SPECIFICATIONS AT 0 TO 50°C Parameter Ports Condition (GHz) Min. Typ. Max. Unit Frequency Range - - 0.1 30 GHz Insertion Loss COM to any active port 0.1 - 10 - 1.40 3.20 dB 10 - 18 - 2.80 4.30 18 - 26 - 3.50 5.30 26 - 30 - 4.40 6.00 Isolation Between ports J1 & J2 0.1 - 10 50 70 - dB 10 - 18 50 60 - 18 - 26 45 55 - 26 - 30 45 55 - COM to any terminated port (including disconnected state) 0.1 - 10 50 60 - 10 - 18 50 65 - 18 - 26 45 55 - 26 - 30 45 55 - Return Loss COM port (in all active states) 0.1 - 10 - 21 - dB 10 - 18 - 15.5 - 18 - 26 - 14.5 - 26 - 30 - 12 - Any port connected to COM 0.1 - 10 - 19 - 10 - 18 - 14.5 - 18 - 26 - 14 - 26 - 30 - 13 - Any terminated port 0.1 - 10 - 19 - 10 - 18 - 16.5 - 18 - 26 - 13.5 - 26 - 30 - 12 - Power Input @1 dB Compression 1 COM to any active port 0.1 - 30 - 27 - dBm IP3 2, 3 COM to any active port 0.5 - 30 - 50 - dBm Transition Time 4 - - - 5 20 ns Minimum Dwell Time 5 High-speed mode - - 10 - µs Switching Time (USB) 6 - - - 2 - ms Supply Voltage (Vcc) USB port - 4.75 5 5.25 V DC Supply Current (Icc) 7 - - 80 120 mA Current Pass-through 8 - - - - 500 mA Operating RF Input Power 1 Between COM & active port Hot switching - - +18 dBm Between COM & active port Cold switching - - +24 Into any termination - - - +24 1. Max power at hot switching derates linearly from +18 dBm @ 600 MHz to +17 dBm @100 MHz, at all other conditions it derates linearly from +24 dBm @ 600 MHz to +17 dBm @100 MHz. 2. IP3 may degrade below 500 MHz to about +45 dBm. 3. IP3 tested with 1 MHz span between signals, +8 dBm per tone. 4. Transition time spec represents the time that the RF signal paths are interrupted during switching and thus is specified without communication delays. 5. Minimum dwell time is the shortest time that can be achieved between 2 switch transitions when programming an automated switch sequence. 6. Switching time (USB) is the time from issuing a single software command via USB to the switch state changing. The most significant factor is the host PC, influenced by CPU load and USB protocol. The time shown is an estimate for a medium CPU load and USB 2.0 connection. 7. USB current draw for a single unit with no slave units. 8. Pass through current is the maximum supply current handling of a unit with slave modules attached. If controlling a large number of slave modules additional power supplies should be included to ensure this limit is not exceeded. See page 5 for details. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |