DMR30-TC1-1-DC4-R-C Datasheet(PDF) 4 Page - Murata Power Solutions Inc.

Part # DMR30-TC1-1-DC4-R-C
Description  Thermocouple Temperature Meter
PDF  10 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  MURATA-PS [Murata Power Solutions Inc.]
Direct Link  http://www.murata-ps.com
Logo MURATA-PS - Murata Power Solutions Inc.

DMR30-TC1-1-DC4-R-C Datasheet(HTML) 4 Page - Murata Power Solutions Inc.

  DMR30-TC1-1-DC4-R-C Datasheet HTML 1Page - Murata Power Solutions Inc. DMR30-TC1-1-DC4-R-C Datasheet HTML 2Page - Murata Power Solutions Inc. DMR30-TC1-1-DC4-R-C Datasheet HTML 3Page - Murata Power Solutions Inc. DMR30-TC1-1-DC4-R-C Datasheet HTML 4Page - Murata Power Solutions Inc. DMR30-TC1-1-DC4-R-C Datasheet HTML 5Page - Murata Power Solutions Inc. DMR30-TC1-1-DC4-R-C Datasheet HTML 6Page - Murata Power Solutions Inc. DMR30-TC1-1-DC4-R-C Datasheet HTML 7Page - Murata Power Solutions Inc. DMR30-TC1-1-DC4-R-C Datasheet HTML 8Page - Murata Power Solutions Inc. DMR30-TC1-1-DC4-R-C Datasheet HTML 9Page - Murata Power Solutions Inc. Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 10 page
background image
DMR30-TC1 Series
Thermocouple Temperature Meter
DMR30-TC1.A01 Page 4 of 10
https://www.murata-ps.com/support
ELECTRICAL CONNECTIONS:
Alarm Relay Connections (back to operation section)
DMR30-TC1 provides a solid-state relay output that ‘closes’ upon alarm condition detection. This circuit is electrically isolated from the meter’s
measurement circuitry and power supply inputs providing a high degree of application flexibility. Caution is required when driving loads having
high inrush current such as incandescent lamps, or inductive loads such as electromechanical relays since associated current and voltage spikes
may damage the meter. When used to drive an inductive load, such as an electromechanical relay, a ‘flyback’ diode should be connected across
the relay coil (ensuring correct polarity so that it will not forward conduct under normal use) to suppress high transient voltages that may damage
the DMR30-TC1, as shown in the following illustration:
DMR30-TC1
RELAYA
RELAYB
ELECTROMECHANICAL
RELAY
‘FLYBACK’
DIODE
Note that the diode must be
connected so that it does not
forward conduct when the
relay is turned on.
DC
SUPPLY
Notes:
•
The alarm relay circuit’s isolation is not intended for use as a safety isolation barrier. The maximum voltage between the alarm relay
terminals (RELAYA or RELAYB) and the thermocouple input terminals (+TC, -TC) or power supply terminals (+VS, -VS) must be limited
to +/-48VDC. The alarm relay is intended to provide an informational signal of over-temperature/under-temperature conditions; for
example driving a piezoelectric siren or LED lamp to signal the condition.
•
The DMR30’s alarm output relay must not be used in the control loop of any type of system where it either directly or indirectly signals
that a heating or cooling element is to be turned on or off, or used as a safety limit switch.
Power Supply Connections
The meter is powered by connection of an external 9VDC to 32VDC source to the +VS and –VS terminals.
Additionally:
•
Isolation: Thermocouple terminals (+TC, -TC) are electrically isolated from the power supply terminals (+VS, -VS). The maximum
voltage between the power supply terminals and the thermocouple input terminals must be limited to +/-48VDC.
•
Protection: The DMR30 series of meters incorporates protection against momentary applications of both overvoltage and reverse
polarity to the power supply (+VS, -VS) terminals. Depending on regulatory and application requirements it may also be necessary for
the user to add external fusing.
Link to additional notes
Screw terminal Location:
Terminal #
Name
Function
1
+TC
Thermocouple inputs
2
-TC
3
+VS
Power supply inputs (9VDC - 32VDC)
4
-VS
5
RELAYB
Solid-state relay alarm outputs
6
RELAYA
Note: It is important to tighten all screw-terminals to their torque specification of 4.5 lbf-in (0.51Nm). Proper tightening will help ensure
reliable operation. Applications subject to vibration should use stranded wire.



Html Pages

1 2 3 4 5 6 7 8 9 10


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com