| Electronic Components Datasheet Search |
|
DMR30-TC1-1-DC4-R-C Datasheet(PDF) 4 Page - Murata Power Solutions Inc. |
|
|
|||||||||||||||||||||||||||||
DMR30-TC1-1-DC4-R-C Datasheet(HTML) 4 Page - Murata Power Solutions Inc. |
|
4 / 10 page ![]() DMR30-TC1 Series Thermocouple Temperature Meter DMR30-TC1.A01 Page 4 of 10 https://www.murata-ps.com/support ELECTRICAL CONNECTIONS: Alarm Relay Connections (back to operation section) DMR30-TC1 provides a solid-state relay output that ‘closes’ upon alarm condition detection. This circuit is electrically isolated from the meter’s measurement circuitry and power supply inputs providing a high degree of application flexibility. Caution is required when driving loads having high inrush current such as incandescent lamps, or inductive loads such as electromechanical relays since associated current and voltage spikes may damage the meter. When used to drive an inductive load, such as an electromechanical relay, a ‘flyback’ diode should be connected across the relay coil (ensuring correct polarity so that it will not forward conduct under normal use) to suppress high transient voltages that may damage the DMR30-TC1, as shown in the following illustration: DMR30-TC1 RELAYA RELAYB ELECTROMECHANICAL RELAY ‘FLYBACK’ DIODE Note that the diode must be connected so that it does not forward conduct when the relay is turned on. DC SUPPLY Notes: • The alarm relay circuit’s isolation is not intended for use as a safety isolation barrier. The maximum voltage between the alarm relay terminals (RELAYA or RELAYB) and the thermocouple input terminals (+TC, -TC) or power supply terminals (+VS, -VS) must be limited to +/-48VDC. The alarm relay is intended to provide an informational signal of over-temperature/under-temperature conditions; for example driving a piezoelectric siren or LED lamp to signal the condition. • The DMR30’s alarm output relay must not be used in the control loop of any type of system where it either directly or indirectly signals that a heating or cooling element is to be turned on or off, or used as a safety limit switch. Power Supply Connections The meter is powered by connection of an external 9VDC to 32VDC source to the +VS and –VS terminals. Additionally: • Isolation: Thermocouple terminals (+TC, -TC) are electrically isolated from the power supply terminals (+VS, -VS). The maximum voltage between the power supply terminals and the thermocouple input terminals must be limited to +/-48VDC. • Protection: The DMR30 series of meters incorporates protection against momentary applications of both overvoltage and reverse polarity to the power supply (+VS, -VS) terminals. Depending on regulatory and application requirements it may also be necessary for the user to add external fusing. Link to additional notes Screw terminal Location: Terminal # Name Function 1 +TC Thermocouple inputs 2 -TC 3 +VS Power supply inputs (9VDC - 32VDC) 4 -VS 5 RELAYB Solid-state relay alarm outputs 6 RELAYA Note: It is important to tighten all screw-terminals to their torque specification of 4.5 lbf-in (0.51Nm). Proper tightening will help ensure reliable operation. Applications subject to vibration should use stranded wire. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |