| Electronic Components Datasheet Search |
|
720XP-1RU Datasheet(PDF) 22 Page - Arista Networks, Inc |
|
|
|||||||||||||||||||||||||||||
720XP-1RU Datasheet(HTML) 22 Page - Arista Networks, Inc |
|
22 / 37 page ![]() 7. Assign a password to the admin username with the username secret command. localhost(config)# username admin secret pxq123 8. Configure a default route to the network gateway. localhost(config)# ip route 0.0.0.0/0 192.0.2.1 9. Assign an IP address (192.0.2.8/24 in this example) to an Ethernet management port. localhost(config)# interface management 1 localhost(config-if-Ma1/1)# ip address 192.0.2.8/24 10. Save the configuration by typing write memory or copy running-config startup-config. localhost# copy running-config startup-config 11. When the management port IP address is configured, select this command to access the switch from a host using the address configured in Step 9: ssh admin@192.0.2.8 Refer to the Arista Networks User Manual for complete switch configuration information. 18 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|