| Electronic Components Datasheet Search |
|
DCA5-20PC-1-DC4-RLC Datasheet(PDF) 2 Page - Murata Power Solutions Inc. |
|
|
|||||||||||||||||||||||||||||
DCA5-20PC-1-DC4-RLC Datasheet(HTML) 2 Page - Murata Power Solutions Inc. |
|
2 / 6 page ![]() ➀ A full-scale input voltage of 50.00mV is used to calibrate all models for their designated measurement range. The ammeter’s rear calibration potentiometer compensates for full-scale input variations up to ±1% (49.5 to 50.5mV). Measuring positive and negative currents (bipolar operation): In applications where both positive and negative currents must be measured, Murata Power Solu- tions recommends using ‘-DC4’ 8-36V isolated supply models. Negative current flow is denoted by the illumination of the display’s negative (–) sign; the absence of a negative sign implies positive current flow. Contact MPS if you have any questions regarding bipolar operation of DCA5-20PC ammeters. ➁ On non-isolated ‘-DC1’ models, continuous application of single-ended ±400mV inputs will not damage the ammeter. Single-ended inputs are defined as those whose TB1-1 (–IN) potential is within ±0.1V of the potential on TB2-2 (-V). For all models, the application of short-duration (5 seconds max.) ±1V inputs will not damage the ammeter. ➂ Breakdown (isolation) voltage applies only to ‘-DC4’ isolated-power models. Breakdown voltage is tested with TB1-1 tied to TB1-2 (–IN shorted to +IN) and TB2-1 tied to TB2-2 (+V shorted to -V). 500Vdc is then applied between the two shorted terminal-block pairs; the max. allowable leakage current is 5uA. ➃ Zero reading is measured with TB1-1 (–IN) shorted to TB1-2 (+IN). ➄ Power supply currents noted are measured with the 50mV shunt input (TB1) at zero volts (display reads “000”) and one decimal point enabled. ➅ Each model’s full-scale display reading with a 50.0mV input is designated by the first X in the DCA5-20PC-X-XXX model number structure. Decimal point selection (DP1, DP2, DP3, or none) is performed by the user to suit desired amperage range. Input ranges -1, -2, -3, -4, -7, -8 and -9 can accommodate 100mV shunts. For these ranges, the indicated 50mV reading is doubled when a 100mV input is applied. Performance/Functional Specifications Typical at TA = +25°C, unless otherwise noted. DCA5-20PC - x - DC1 - R L - C Power Supply: DC1 = +5-40Vdc, non-isolated power (available with -RL, -BL, or -PGL LEDs) DC4 = +8-36Vdc, isolated power (available with -RL, -BS, or -GS LEDs) LED Color: BL = Low-Power Blue BS = Super Blue GS = Standard Green PGL = Low-Power Green RL = Low-Power Red Accessories: DMS-20-CP Panel Cutout Punch A DMS-BZL4-C bezel assembly with sealing gasket is supplied with each ammeter. Shunt Model Rating Use with 3020-01097-0 5A/50mV DCA5-20PC-1 3020-01107-0 10A/100mV DCA5-20PC-1 3020-01098-0 20A/50mV DCA5-20PC-6 3020-01096-0 50A/50mV DCA5-20PC-1 3020-01099-0 100A/50mV DCA5-20PC-2 3020-01108-0 100A/100mV DCA5-20PC-1 3020-01100-0 150A/50mV DCA5-20PC-5 3020-01101-0 200A/50mV DCA5-20PC-6 3020-01102-0 300A/50mV DCA5-20PC-3 3020-01103-0 500A/50mV DCA5-20PC-1 3020-01104-0 800A/50mV DCA5-20PC-10 3020-01105-0 1000A/50mV DCA5-20PC-2 3020-01106-0 1200A/50mV DCA5-20PC-11 Input (TB1) ➀ Min. Typ. Max. Units Full Scale Input ➀ 49.5 50 50.5 mV Overvoltage Rating ➁ ±400 – – mV Input Impedance – 1K – Ohms Shunt Input to Power Supply Isolation ➂ DCA-20PC-X-DC4 models only 500 – – Vdc Performance Sampling Rate 2.5 reading per second Accuracy ±0.15%FS Zero-Current Reading ➃ “–001” “000” “001” Counts Temperature Drift (0 = +60°C) – ±0.2 ±0.4 Cnts/°C Power Supply Voltage (TB2) DCA-20PC-X-DC1-XX +5.0 – +40 Vdc DCA-20PC-X-DC4-XX +8 – +36 Vdc Power Supply Current ➄ DCA-20PC-X-DC1-XX (@ 5-40V) – 10 15 mAdc DCA-20PC-X-DC4-XX (@ 8V) – 100 150 mAdc DCA-20PC-X-DC4-XX (@ 36V) – 25 40 mAdc TB1 and TB2 Terminal Blocks Wire Size 16-22AWG, solid or stranded Insulation Strip Length 0.250 inches Screw Tightening Torque 2.2 lb·in (0.25 N·m) ±20% Rated Current 20A with 12AWG solid copper wire; 15A with 14AWG solid or stranded copper wire Display Display Type and Size 3½ digit, 0.37"/9.4mm high red, blue or green LED Overrange Indication "–1_ _ _" for negative Vin "1_ _ _" for positive Vin Display Reading/Decimal Point Model dependent Physical/Environmental Operating Temperature 0 – +60 °C Storage Temperature –20 – +75 °C Humidity (non-condensing) 0 – 85 % Case Material Polycarbonate Dimensions 1.38"W x 0.88" x 1.0" nominal Weight 0.6 ounces (17 grams) Ordering Information Add -C for RoHS Use with these 50mV shunts* or with these 100mV shunts* 1 5A 50A 500A 10A 100A 1000A 2 1A 10A 100A 1000A 2A 20A 200A 2000A 3 30A 300A 60A 600A 4 75A 750A 15A 150A 1500A 5 15A 150A 1500A — 6 2A 20A 200A 2000A — 7 25A 250A 5A 50A 500A 8 400A 80A 800A 9 600A 120A 1200A 10 80A 800A — 11 1200A — *With respective decimal point user enabled. See technical note 7. Input Range: See www.murata-ps.com/dpm-availability for model-specific availability. www.murata-ps.com/support DCA5-20PC Series 50mV & 100mV Input, LED-Display, Subminiature DC Ammeters MPM_DCA5-20PC.C01 Page 2 of 6 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |