5 / 6 page ![]() APPLICATIONS PANEL INSTALLATION Step 1. Step 2. Step 3. Step 4. 8. Operation With 100mV Shunts: Many DCA5-20PC Series ammeters can also operate with 100mV shunts. This is due to the fact that when they are driven by a 100mV input, the display readings are double those of a 50mV input. However, a 50mV shunt cannot be used in a 100mV application because its maximum current rating will be exceeded. For our customer’s convenience, Murata Power Solutions offers a series of 50mV and 100mV chassis-mount dc shunts that can be used with DCA5-20PC ammeters. Part numbers for accessory shunts can be found in the Ordering Information section. A data sheet describing these shunts is available at www.murata-ps.com. Table 1 indicates the obtainable readings of the seven DCA5-20PC models that can be operated with 100mV shunts. Be sure to enable the correct decimal point (see decimal point selection instructions). 9. Noisy Power Supplies: Some power supplies contain high-frequency switching devices that may conduct and/or radiate significant noise onto the low-level 50/100mV shunt signal. Even though the DCA5- 20PC incorporates built-in filtering at its shunt input, some portion of this noise may be amplified and subsequently measured by the DCA5- All connections and modifications must be made after the ammeter is securely attached to the panel, with all load and supply voltages de-energized (off). The installed wire-positions should be such that minimal forces are applied to TB1, TB2, and the ammeter itself. In high-vibration environments, the use of wiring strain-reliefs is recommended. To insure a secure panel-mount installation, MPS recommends using the DMS-BZL4-C (with sealing gasket) bezel assembly supplied with each 20PC’s sensitive circuitry. The amplified noise introduces errors that are particularly noticeable at zero load current (i.e., the ammeter may not display a relatively steady “000” reading). Connecting an external, unpolarized capacitor across TB1’s “+” and “–” inputs, and/or across the shunt’s 50mV output terminals, can help reduce noise-related display errors. In certain situations, the use of twisted pair or shield wiring may be required. As a general rule, avoid using excessively long leads between the ammeter and the shunt. Figure 8. Panel Installation ammeter. See the Mechanical Specifications section for detailed panel cutout and ammeter dimensions. Following the four-step sequence shown in Figure 8 below, being careful not to apply excessive force or twisting motions, insert the ammeter into the panel opening. When using the DMS-BZL4-C’s sealing gasket, make sure it is positioned between the ammeter’s flange and the panel’s front surface. Be sure to use and securely tighten all four screws supplied with the bezel assembly. Model 100mV Shunt Readings DCA5-20PC-1 10.00A/100.0A/1000A DCA5-20PC-2 1.999A/19.99A/199.9A/1999A DCA5-20PC-3 60.0A/600A DCA5-20PC-4 150.0A/1500A DCA5-20PC-7 50.0A/500A DCA5-20PC-8 800A DCA5-20PC-9 1200A Table 1. 100mV Shunt Readings * * With respective decimal point enabled 2 1 3 4 www.murata-ps.com/support DCA5-20PC Series 50mV & 100mV Input, LED-Display, Subminiature DC Ammeters MPM_DCA5-20PC.C01 Page 5 of 6 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |