3 / 6 page ![]() –IN – +IN + –V +V LOAD 50mV SHUNT DC SUPPLY 5-40Vdc POWER GROUND (0Vdc) LOAD CURRENT J3 MUST BE INSTALLED (FACTORY SETTING) FOR 5-40Vdc SUPPLIES J1 AND J2 POSITIONS DEPEND ON INPUT RANGE DCA5-20PC-X-DC1-XX SHUNT MUST BE IN LOW SIDE 1 1 1 2 2 CAL TB1 TB2 J1 J2 J3 1 1 2 2 3 1 2 1 1 1 2 2 CAL TB1 TB2 J1 J2 J3 1 1 2 2 3 1 2 –IN – +IN + –V +V LOAD 50mV SHUNT DC SUPPLY 36-75Vdc POWER GROUND (0Vdc) LOAD CURRENT REMOVE J3 FOR 36-75Vdc SUPPLIES SHUNT MUST BE IN LOW SIDE DCA5-20PC-X-DC1-XX TECHNICAL NOTES Figure 2. Low-Side Shunt Connections for "-DC1" 5-40Vdc Non-Isolated Supply Models To ensure safe and reliable operation, DCA5-20PC dc ammeters must only be installed and serviced by qualified technical personnel. DC ammeter applications can expose a user to potentially lethal currents and voltages. Power and signal connections must be made with all associ- ated power sources de-energized. Contact Murata Power Solutions if you have any questions regarding the installation or operation of any of our digital instruments. 1. Calibration: DCA5-20PC ammeters are designed to operate with 50mV and 100mV dc shunts whose rated accuracy is ±0.25%, or better. The output of less accurate shunts may fall outside the ammeter’s ±1% calibra- tion adjustment range. Under normal indoor operating conditions, periodic recalibration of DCA5-20PC ammeters is not necessary. The calibration potentiometer, located on the back of the ammeter, is a ¾ turn type; do not force its adjustment screw past the two end stops. If user calibration is deemed necessary, it must be performed by qualified personnel. Calibration is performed by applying a precision 50.00mVdc or 100mVdc (model specific, see ordering guide) signal to TB1, observing correct polarity. Then, using an insulated slotted tool, adjust the calibration potentiometer until the correct display reading is achieved. Contact MPS if additional information is required regarding calibration or setup of DCA5- 20PC ammeters. 2. Wiring and Fusing: Power supply (TB2) and input (TB1) wiring must be rated for the electrical and environmental conditions under which the ammeters will be operated. They must also comply with any regulatory or application-mandated requirements pertaining to the user’s installation. Con- nections to DCA5-20PC ammeters must be made with all power sources de-energized. Refer to the Functional Specifications section for TB1 and TB2 wire gauge information. DCA5-20PC ammeters’ shunt (TB1) and power supply inputs (TB2) are not internally fused. Therefore, the supply wires connected to the meter and the load should be fused according to the maximum current rating (or lower) of the wire gauge used, in accordance with applicable regulatory codes. Insulation should be stripped to within +/-10% of the stated dimensions. All wires must be inserted into the terminal block openings such that the screw terminal does not pinch any insulation. TB2 is to be used solely for power- ing the meter’s internal circuitry; it must not be used to supply current to an external load or auxiliary device. 3. Terminal Block Torque Ratings: It is important to tighten TB1’s and TB2’s screw-terminals to their rated torque specifications of 3.6 pound-inches (0.4Nm). Proper tightening will minimize losses and ensure reliable operation. 4. High-Side versus Low-Side Shunts: Incorrect shunt connections are one of the most common problems encountered when applying digital dc-ammeters. Incorrect shunt connections can cause permanent damage to the ammeter and/or its associated equipment. Low-Side Shunts: Applications that employ a single power supply to power both the load and the ammeter, and the external shunt is located in the negative side of the supply (commonly referred to as “low side” or “grounded shunt”) should use ‘-DC1’ non-isolated power DCA5-20PC Series ammeters. Figures 2, 3, and 4 depict typical low-side shunt connections. High-Side Shunts: ‘-DC4’ isolated-power ammeters must be used in all applications that employ a single power supply to power both the load and the ammeter and the shunt is located in the high side (positive terminal) of the supply. Figures 5 and 6 depict typical high-side shunt connections. As shown in Figure 6, isolated-power models can also be used in applications Figure 3. Low-Side Shunt Connections for "-DC1" Models Modified for 36-75Vdc Non-Isolated Power (See Technical Note 5) where one supply powers the ammeter and a second supply powers the load, but the two supply grounds cannot be tied together. ‘-DC4’ isolated- supply models include a built-in dc/dc converter to provide a minimum of 500Vdc isolation between the shunt (TB1) and power supply inputs (TB2). 5. Operation With 36 to 75Vdc Power: As shipped, all ‘-DC1’ models’ rated operating supply range is +5 to +40Vdc. However, ‘-DC1’ models can be user configured for 36 to 75Vdc operation by removing (opening) jumper J3. Please note that this user modification can only be performed on ‘-DC1 power models. Also, all ‘-DC1’ models – including those that have been modified for 36-75Vdc operation – can only be connected in low-side, grounded-shunt applications. See Figure 3 for detailed wiring information. www.murata-ps.com/support DCA5-20PC Series 50mV & 100mV Input, LED-Display, Subminiature DC Ammeters MPM_DCA5-20PC.C01 Page 3 of 6 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |