Back Button MB89R119B Datasheet HTML 18Page - RAMXEED LIMITED MB89R119B Datasheet HTML 19Page - RAMXEED LIMITED MB89R119B Datasheet HTML 20Page - RAMXEED LIMITED MB89R119B Datasheet HTML 21Page - RAMXEED LIMITED MB89R119B Datasheet HTML 22Page - RAMXEED LIMITED MB89R119B Datasheet HTML 23Page - RAMXEED LIMITED MB89R119B Datasheet HTML 24Page - RAMXEED LIMITED MB89R119B Datasheet HTML 25Page - RAMXEED LIMITED MB89R119B Datasheet HTML 26Page - RAMXEED LIMITED Next Button
Zoom Inzoom in Zoom Outzoom out
 22 / 46 page
background image
MB89R119B
22
DS411-00002-4v0-E
12. Timing definitions
(1)Transponder waiting time before transmitting its response after reception of an EOF from the reader/writer
: t1_a
After detection of an EOF signal sent from the reader/writer, each transponder must wait for a certain time
(t1_a) before sending a response to the reader/writer. t1_a begins at the rising edge of the EOF pulse, and
it is defined as follows.The minimum value is 4320/fc (318.6 s), the nominal value is 4352/fc (320.9 s),
and the maximum value is 4384/fc (323.3 s).
If the transponder detects a carrier modulation for ASK 100% or 10% within the time t1_a, it shall reset its
t1_a timer and wait for further time t1_a before starting to transmit its response to a reader/writer.
MB89R119B defines the same waiting time t1_a for Write commands as follows, although the maximum
value is not defined in ISO/IEC 15693-3 and ISO/IEC 18000-3 (Mode 1) . The minimum value is 4320/fc
(318.6 s), the nominal value is 4352/fc (320.9 s), and the maximum value is 4384/fc (323.3 s).Timing
conditions for Write command in which the option_flag is “1”, has optional field are defined in the command
descriptions.
(2) Transponder modulation ignore time after reception of an EOF from the reader/writer : tmit
After detection of an EOF signal sent from the reader/writer, MB89R119B shall ignore any received 10%,
modulation during tmit. tmit starts from the detection of the rising edge of the EOF, and the minimum value
is defined as 4384/fc (323.3 s)  tnrt. tnrt stands for the response time of MB89R119B.
(3) Reader/writer waiting time before sending a subsequent request : t2_a
When the reader/writer has received a response from the transponder to a previous request other than
Inventory and Quiet command, it shall wait a time t2_a before sending a subsequent request. The minimum
value of t2_a is 309.2 s. It is defined in ISO/IEC 15693-3 and ISO/IEC 18000-3 (Mode 1) .
When the reader/writer has sent Stay Quiet command or Kill command, which causes no response from the
transponder, or MB89R119B does not return any response, MB89R119B can receive a command in
309.2 s from the detection of the rising edge of the EOF.
(4) Reader/writer waiting time before sending a request(switching to the next slot) during an Inventory process
: t2inv
During Inventory process, the reader/writer sends an EOF to switch to the next slot. In this case, the waiting
time is defined as follows depending on whether transponders return responses.
- Waiting time applied when the reader/writer has received one or more responses : t2invwr
It is defined in ISO/IEC 15693-3 and ISO/IEC 18000-3 (Mode 1) that when the reader/writer has received
one or more responses, the reader/writer must wait until responses from the transponders have been
completed (that is, the reader/writer receives an EOF or tnrt passes). After that, the reader/writer must
wait as additional t2_a, and then send a 10% or 100% ASK modulated EOF to switch to the next slot.
- Waiting time applied for when the reader/writer has not received any responses : t3_a
When the reader/writer has not received any responses from the transponders, the reader/writer must
wait until t3_a passes before sending an EOF signal. In this case, t3_a starts from the rising edge of the
last sent EOF. The minimum value of t3_a is defined as shown in the following table.
(a) If the reader/writer sends a ASK10% modulated EOF,
the minimum value of t3_a (ASK 10%) is ’4384/fc (323.3 s) + tnrt’.
(b) If the reader/writer sends a ASK100% modulated EOF,
the minimum value of t3_a (ASK 100%) is ’4384/fc (323.3 s) + tsof’.
tnrt : The nominal response time of transponder
tsof : The time for transponder to transmit a SOF to the reader/writer



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com