| Electronic Components Datasheet Search |
|
MB89R119B Datasheet(PDF) 27 Page - RAMXEED LIMITED |
|
|
|||||||||||||||||||||||||||||
MB89R119B Datasheet(HTML) 27 Page - RAMXEED LIMITED |
|
27 / 46 page ![]() MB89R119B DS411-00002-4v0-E 27 2-3. Lock Block command On receiving the Lock Block command, the transponder locks (write disable) permanently the requested block. The transponder performs verification after writing and returns an error code if the writing has failed. If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the lock operation starting after “t1nom (320.9 s) + a multiple of 4096/fc (302.1 s)” with total tolerance of 32/fc (2.4 s) and latest within 20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/ writer and upon such reception still return its response. (However, if an EOF is not sent within 38 ms, the time-out occurs and the transponder can receive another command.) Once the Lock Block command has been received, data in the locked block cannot be changed by the Write commands. Request (from the reader/writer to the transponder) Response (from the transponder to the reader/writer) (1) When Error_flag set (2) When Error_flag not set 2-4. Read Multiple Blocks Command On receiving the Read Multiple Blocks command, the transponder reads the requested block(s) and returns their value in the response. Up to 64 blocks of data can be read for one request. If the Option_flag (bit 7) is “1”, the transponder adds block security status information in the response. If the Option_flag (bit 7) is “0”, the transponder returns only the data in the specified blocks to the reader/writer. The value of the "number of blocks" field specified in the request is the expected number of blocks minus 1. Setting the number of blocks to “06H” makes a request to read 7 blocks. Setting the number of blocks to “00H” makes a request to read 1 block (the request having the same effect as the Read Single Block command). The maximum number of blocks to be set is “3FH”. Request (from the reader/writer to the transponder) SOF Flags Command (Lock Block) UID (Addressed mode) Block number CRC EOF 8 bits 8 bits (“22H”) 64 bits 8 bits 16 bits SOF Flags Error code CRC EOF 8 bits (“01H”) 8 bits 16 bits SOF Flags CRC EOF 8 bits (“00H”) 16 bits SOF Flags Command (Read Multiple Blocks) UID (Addressed mode) First block number Number of blocks CRC EOF 8 bits 8 bits (“23H”) 64 bits 8 bits 8 bits 16 bits |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |