| Electronic Components Datasheet Search |
|
SPC582B50E3 Datasheet(PDF) 99 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
SPC582B50E3 Datasheet(HTML) 99 Page - STMicroelectronics |
|
99 / 111 page ![]() DS11597 Rev 5 99/111 SPC582B60x, SPC582B54x, SPC582B50x Package information 99 mm of wire extending from the junction. Place the thermocouple wire flat against the package case to avoid measurement errors caused by the cooling effects of the thermocouple wire. When board temperature is perfectly defined below the device, it is possible to use the thermal characterization parameter ( ΨJPB) to determine the junction temperature by measuring the temperature at the bottom center of the package case (exposed pad) using the following equation: Equation 5 TJ = TB + (ΨJPB x PD) where: TT = thermocouple temperature on bottom of the package (°C) ΨJT = thermal characterization parameter (°C/W) PD = power dissipation in the package (W) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |