Back Button TLV172IDCKT.B Datasheet HTML 15Page - Texas Instruments TLV172IDCKT.B Datasheet HTML 16Page - Texas Instruments TLV172IDCKT.B Datasheet HTML 17Page - Texas Instruments TLV172IDCKT.B Datasheet HTML 18Page - Texas Instruments TLV172IDCKT.B Datasheet HTML 19Page - Texas Instruments TLV172IDCKT.B Datasheet HTML 20Page - Texas Instruments TLV172IDCKT.B Datasheet HTML 21Page - Texas Instruments TLV172IDCKT.B Datasheet HTML 22Page - Texas Instruments TLV172IDCKT.B Datasheet HTML 23Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 19 / 49 page
background image
19
TLV172, TLV2172, TLV4172
www.ti.com
SBOS784C – NOVEMBER 2016 – REVISED JANUARY 2019
Product Folder Links: TLV172 TLV2172 TLV4172
Submit Documentation Feedback
Copyright © 2016–2019, Texas Instruments Incorporated
8.4 Device Functional Modes
8.4.1 Common-Mode Voltage Range
The input common-mode voltage range of the TLVx172 device extends 100 mV below the negative rail and
within 2 V of the top rail for normal operation.
This device can operate with full rail-to-rail input 100 mV beyond the top rail, but with reduced performance within
2 V of the top rail. Table 2 lists the typical performances in this range.
Table 2. Typical Performance for Common-Mode Voltages Within 2 V of the Positive Supply
PARAMETER
MIN
TYP
MAX
UNIT
Input common-mode voltage
(V+) – 2
(V+) + 0.1
V
Offset voltage
7
mV
Offset voltage vs temperature
12
µV/°C
Common-mode rejection
65
dB
Open-loop gain
60
dB
Gain-bandwidth product
0.3
MHz
Slew rate
0.3
V/µs
8.4.2 Overload Recovery
Overload recovery is defined as the time required for the operational amplifier output to recover from the
saturated state to the linear state. The output devices of the operational amplifier enter the saturation region
when the output voltage exceeds the rated operating voltage, which is a result from the high input voltage or the
high gain. After the device enters the saturation region, the charge carriers in the output devices require time to
return back to the normal state. After the charge carriers return back to the equilibrium state, the device begins to
slew at the normal slew rate. As a result, the propagation delay in case of an overload condition is the sum of the
overload recovery time and the slew time. The overload recovery time for the TLVx172 is approximately 2 µs.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com