| Electronic Components Datasheet Search |
|
AS3715 Datasheet(PDF) 71 Page - ams-OSRAM AG |
|
|
|||||||||||||||||||||||||||||
AS3715 Datasheet(HTML) 71 Page - ams-OSRAM AG |
|
71 / 159 page ![]() Page 70 ams Datasheet Document Feedback [v1-03] 2015-Aug-10 AS3715 − Detailed Description – System Functions Figure 72: Temperature Supervision Characteristics Temperature Supervision Characteristic: Shows the key electrical parameter of the over-temperature supervision. Temperature Supervision SD4 (Sub Die) A similar supervision is installed for the power stage controlled by SD4. temp_sd4_alarm and temp_sd4_shutdown are indicating a >110°C or >140°C temperature condition of the sub die. For both events an interrupt can be triggered. With mask_ovtemp=0 reaching 140°C is initiating a reset cycle. If mask_ovtemp=1 only an interrupt is generated (if enabled) Watchdog Description The purpose of the watchdog is to detect a deadlock of the software. If the watchdog is active, it must receive a continuous trigger signal within a programmable time window. If there is no signal anymore for a certain time period from a defined pad or special serial interface bit, it starts either a complete reset cycle or initiates the power OFF sequence. The watchdog is highly configurable by the following register bits: • The complete block can be switched ON by wtdg_on = 1 and OFF by wtdg_on = 0. • The watchdog time window is defined by the register wtdg_timer between 1s and 128s. • The trigger signal can be either triggered by setting wtdg_sw_sig or using a HW signal on one of the GPIO pins (gpioX_iosf=9). • If the watchdog expires, the system can start automatically a reset cycle if wtdg_reset_on = 1 and wtdg_pweroff = 0, or perform a power down if wtdg_reset_on = 1 and wtdg_pweroff = 1. • If wtdg_reset_on = 0 and wtdg_pweroff = 0 only an interrupt is generated (if the interrupt is enabled) • Whether the watchdog caused a reset can be seen in the reset_reason. Symbol Parameter Conditions Min Typ Max Unit T110 ov_temp_110 rising threshold 95 110 125 ºC T140 ov_temp_140 rising threshold 125 140 155 ºC Thyst ov_temp_110 and ov_temp_140 hysteresis 5ºC |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |