| Electronic Components Datasheet Search |
|
CS-LDTC01 Datasheet(PDF) 1 Page - Wavelength Electronics, Inc. |
|
|
|||||||||||||||||||||||||||||
CS-LDTC01 Datasheet(HTML) 1 Page - Wavelength Electronics, Inc. |
|
1 / 3 page ![]() © 2017 • Sales & Technical Support: (406) 587-4910 • email: sales@teamWavelength.com • web: www.teamWavelength.com Case Study CS-LDTC01 Rev. A Utilizing Quantum Cascade Lasers for Gas Sensing in the Mid-Infrared April, 2017 Page 1 ABSTRACT Using Wavelength Electronics' precision temperature controller and low noise Quantum Cascade Laser (QCL) driver, researchers at Princeton University developed a sensor that was designed around a QCL to simultaneously measure nitrous oxide (N 2O) and carbon monoxide (CO). The sensor is compact and field-deployable, requiring much less power and having a much smaller footprint and mass than previous sensors, while increasing the accuracy of concentration measurements. The most accurate measurements were 0.15 parts-per-billion-by-volume (ppbv) for N 2O and 0.36 ppbv for CO. These accuracies well exceed the requirement of 1 ppbv to be considered "high stability" in the field of atmospheric sensing. WHY? Nitrous oxide (N 2O) is a greenhouse gas that poses a greater threat to global warming potential than carbon dioxide, and is currently increasing in the atmosphere. The understanding of what is driving this increase, and whether it is human-related is an important scientific question that remains unanswered. Part of the reason that the question surrounding N 2O is still unanswered is that its emissions are poorly constrained in both space and time, making it difficult to measure. Another driving factor for confusion with respect to N 2O is that atmospheric levels fluctuate naturally, as nitrogen levels in the soil and bodies of water change. Simultaneous detection of N 2O and CO concentrations allows identification of natural and fossil fuel combustion sources of N 2O. Portability of the sensor is necessary for making field measurements. This allows data to be collected during natural or human-caused fluctuations, and to find correlations between outdoor weather and rises in N 2O concentrations. PROBLEMS WITH OLD SENSORS Systems that were designed prior to the advent of QCLs required bulky laser systems that had mid-infrared (mid-IR) emission wavelengths. These lasers generally also required large cooling mechanisms, which added to the footprint and the overall mass of the system. Older systems also didn't have high enough accuracy for the required measurements. Another shortfall that many of the previous systems had is that they were designed to be able to take measurements in a laboratory environment, and were not easily (if at all) transferrable to the field to take measurements. Previous systems also commonly employed a closed-path setup, which is prone to sampling artifacts due to the tubes and vacuums that are required for closed-path sensing. Additionally, these closed-path geometries were ill-suited for handling high-frequency changes in the measurement, and would frequently broaden the data if a high frequency change were to occur. |
Similar Part No. - CS-LDTC01 |
|
Similar Description - CS-LDTC01 |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |