325 / 496 page ![]() 2010 Microchip Technology Inc. Preliminary DS41412C-page 325 PIC18(L)F2X/4XK22 19.4 Measuring Capacitance with the CTMU There are two separate methods of measuring capacitance with the CTMU. The first is the absolute method, in which the actual capacitance value is desired. The second is the relative method, in which the actual capacitance is not needed, rather an indication of a change in capacitance is required. 19.4.1 ABSOLUTE CAPACITANCE MEASUREMENT For absolute capacitance measurements, both the current and capacitance calibration steps found in Section 19.3 “Calibrating the CTMU Module” should be followed. Capacitance measurements are then performed using the following steps: 1. Initialize the A/D Converter. 2. Initialize the CTMU. 3. Set EDG1STAT. 4. Wait for a fixed delay, T. 5. Clear EDG1STAT. 6. Perform an A/D conversion. 7. Calculate the total capacitance, CTOTAL = (I * T)/V, where I is known from the current source measurement step (see Section 19.3.1 “Current Source Calibration”), T is a fixed delay and V is measured by performing an A/D conversion. 8. Subtract the stray and A/D capacitance (COFFSET from Section 19.3.2 “Capacitance Calibration”) from CTOTAL to determine the measured capacitance. 19.4.2 RELATIVE CHARGE MEASUREMENT An application may not require precise capacitance measurements. For example, when detecting a valid press of a capacitance-based switch, detecting a rela- tive change of capacitance is of interest. In this type of application, when the switch is open (or not touched), the total capacitance is the capacitance of the combina- tion of the board traces, the A/D Converter, etc. A larger voltage will be measured by the A/D Converter. When the switch is closed (or is touched), the total capacitance is larger due to the addition of the capacitance of the human body to the above listed capacitances, and a smaller voltage will be measured by the A/D Converter. Detecting capacitance changes is easily accomplished with the CTMU using these steps: 1. Initialize the A/D Converter and the CTMU. 2. Set EDG1STAT. 3. Wait for a fixed delay. 4. Clear EDG1STAT. 5. Perform an A/D conversion. The voltage measured by performing the A/D conversion is an indication of the relative capacitance. Note that in this case, no calibration of the current source or circuit capacitance measurement is needed. See Example 19-4 for a sample software routine for a capacitive touch switch. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |