| Electronic Components Datasheet Search |
|
FX829 Datasheet(PDF) 11 Page - CML Microcircuits |
|
|
|||||||||||||||||||||||||||||
FX829 Datasheet(HTML) 11 Page - CML Microcircuits |
|
11 / 34 page ![]() Baseband Signal Processor FX829 © 1997 Consumer Microcircuits Limited 11 D/829/4 MIC (Bit 1) When this bit is "1", the MIC input is enabled and the AMP1 (DEMODIN) input is disabled. When this bit is "0", the AMP1 (DEMODIN) input is enabled and the MIC input is disabled. B/W (Bit 0) When this bit is "1", the bandwidth of the audio path is set wide for 20kHz/25kHz RF channel spacing. When this bit is "0", the bandwidth of the audio path is set narrow for 12.5kHz RF channel spacing. CONTROL 2 Register (Hex address $11) This register is used to control the functions of the device as described below: CHKSUM (Bit 7) In the Tx mode, when this bit is "1", the checksum generator is enabled. All complete bytes that are transmitted after this time are used in the checksum calculation. When this bit goes from "1" to "0", the checksum generator will complete its calculations on the current byte and the result will be sent as the next two bytes of transmitted data. In the Rx mode, the "0" to "1" transition of the CHKSUM bit is used at the start of the next byte received at DEMODIN to manually reset the Rx checksum calculation, see Figure 4. The calculation can also be reset automatically by a SYNC, SYNT, or RX SYNC WORD detection - see CONTROL 3 / IRQ ENABLE Register. In this case, the Rx checksum calculation starts with the first data byte after the 2-byte sync word has been detected. The CHKSUM bit can be reset to "0" at any time. The result of the checksum is made available in the STATUS Register after the reception of every complete byte (See RXSUMF bit of the STATUS Register). Note that the device is designed to work with any message length, and as a consequence it is not aware of the position of the checksum within the incoming data message. It thus performs a checksum assessment after every received byte. The controlling software should use its knowledge of the system message length in order to determine which RXSUMF reading is valid, i.e. after the second of the two checksum bytes has been received. The timing of data bytes relative to the checksum bit is shown in Figures 3 and 4. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |