| Electronic Components Datasheet Search |
|
WM8903CLGEFK/R Datasheet(PDF) 37 Page - Wolfson Microelectronics plc |
|
|
|||||||||||||||||||||||||||||
WM8903CLGEFK/R Datasheet(HTML) 37 Page - Wolfson Microelectronics plc |
|
37 / 178 page ![]() Production Data WM8903 w PD, Rev 4.5, June 2012 37 ELECTRET CONDENSER MICROPHONE INTERFACE Electret Condenser microphones may be connected as single-ended or differential inputs to the Input PGAs described in the “Analogue Input Signal Path” section. The WM8903 provides a low-noise reference voltage suitable for biasing electret condenser microphones. The MICBIAS reference is provided on the MICBIAS pin. This reference voltage is enabled by setting the MICBIAS_ENA register bit, as defined in Table 6. REGISTER ADDRESS BIT LABEL DEFAULT DESCRIPTION R6 (06h) Mic Bias Control 0 0 MICBIAS_ENA 0 MICBIAS Enable 0 = disabled 1 = enabled Table 6 MICBIAS Control MICBIAS CURRENT DETECT A MICBIAS Current Detect function is provided for external accessory detection. This is provided in order to detect the insertion/removal of a microphone or the pressing/releasing of the microphone ‘hook’ switch; these events will cause a significant change in MICBIAS current flow, which can be detected and used to generate a signal to the host processor. The MICBIAS current detect function is enabled by setting the MICDET_ENA register bit. When this function is enabled, two current thresholds can be defined, using the MICDET_THR and MICSHORT_THR registers. When a change in MICBIAS current which crosses either threshold is detected, then an interrupt event can be generated. In a typical application, accessory insertion would be detected when the MICBIAS current exceeds MICDET_THR, and microphone hookswitch operation would be detected when the MICBIAS current exceeds MICSHORT_THR. The current detect threshold functions are both inputs to the Interrupt control circuit and can be used to trigger an Interrupt event when either threshold is crossed. Both events can also be indicated as an output on a GPIO pin - see “General Purpose Input/Output (GPIO)”. The current detect thresholds are enabled and controlled using the registers described in Table 7. Performance parameters for this circuit block can be found in the “Electrical Characteristics” section. Hysteresis and filtering is also provided in the both current detect circuits to improve reliability in conditions where AC current spikes are present due to ambient noise conditions. These features are described in the following section. Further guidance on the usage of the MICBIAS current monitoring features is also described in the following pages. REGISTER ADDRESS BIT LABEL DEFAULT DESCRIPTION R6 (06h) Mic Bias Control 0 5:4 MICDET_THR [1:0] 00 MICBIAS Current Detect Insertion Threshold 00 = 0.063mA 01 = 0.26mA 10 = 0.45mA 11 = 0.635mA Values are scaled with AVDD. Figures shown are based on AVDD=1.8V. 3:2 MICSHORT_TH R [1:0] 00 MICBIAS Short Circuit Button Push Threshold 00 = 0.52mA 01 = 0.77mA 10 = 1.2mA 11 = 1.43mA Values are scaled with AVDD. Figures shown are based on AVDD=1.8V. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |