26 / 56 page ![]() 26 AT25DF641 3680F–DFLASH–4/10 If the desire is to only change the SPRL bit without performing a G lobal Protect or Global Unprotect, then the system can simply write a 0Fh to the first byte of the Status Register to change the SPRL bit from a logical “1” to a logical “0” provided the pin is deasserted. Likewise, the system can write an F0h to change the SPRL bit from a logical “0” to a logical “1” without affecting the current sector protection status (no changes will be made to the Sector Protection Registers). When writing to the first byte of the Status Register, bits five, four, three, and two will not actually be modified but will be dec oded by the device for the purposes of the Global Protect and G lobal Unprotect functions. Only bit seven, the SPRL bit, will actually be modified. Therefore, when reading the first byte of the Status Register, bits five, four, three, and two will not reflect the values written to them but will instead indicate the status of the pin and the sector protection status. Please refer to “Status Register Commands” on page 34 and Table 10-1 on page 34 for details on the Status Register format and what values can be read for bits five, four, three, and two. 8.6. Read Sector Protection Registers The Sector Protection Registers can be read to determine the current software protection status of each sector. Reading the Sector Protection Registers, however, will not determine the status of the pin. To read the Sector Protection Register for a particular sector, the pin must first be asserted and the opcode of 3Ch must be clocked in. Once the opcode has been clocked in, three address bytes designating any address within the sector must be clocked in. After the last address byte has been clocked in, the device will begin outputting data on the SO pin during every subsequent clock cycle. The data being output will be a repeating byte of either FFh or 00h to denote the value of the appropriate Sector Protection Register. At clock frequencies above fCLK, the first byte of data output will not be v alid. Therefore, if operating at clock frequencies above fCLK, at least two bytes of data must be clocked out from the device in order to determine the correct status of the appropriate Sector Protection Register. Table 8-3. Read Sector Protection Register - Output Data Output Data Sector Protection Register Value 00h Sector Protection Register value is 0 (sector is unprotected) FFh Sector Protection Register value is 1 (sector is protected) Deasserting the pin will terminate the read operation and put the SO pin into a high-impedance state. The pin can be deasserted at any time and does not require that a full byte of data be read. In addition to reading the individual Sector Protection Registers, the Software Protection Status (SWP) bits in the Status Register can be r ead to determine if all, some, or none of the sectors are software protected (refer to “Read Status Register” on page 34 for more details). CS CS CS WP WP WP |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |