17 / 22 page ![]() AN4117 Receiver parameters Doc ID 023222 Rev 1 17/22 Figure 18. RX blocking vs. CW interferer offset with 1% BER, 100 kHz channel Figure 19. RX blocking vs. CW interferer offset with 1% BER, 500 kHz channel 3.3 Receiver spurious radiation Spurious radiations from the receiver are components at any frequency, radiated by the equipment. A spectrum analyzer is used as the external receiver. The measurement is performed setting the SPIRIT1 with modulation and checking receiver spurious emissions up to 4 GHz as described in ETSI [2] subclause 8.6. The measurement is split into two figures: in Figure 20 the spurious radiation for frequency below 1 GHz is shown. The measurement is performed setting the instrument in max. hold with a resolution bandwidth of 100 kHz, as requested in ETSI [2]. In Figure 21 the spurious radiation for frequencies from 1 GHz to 4 GHz is shown. The measurement is performed |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|