Back Button AFE1302Y/2K Datasheet HTML 3Page - Texas Instruments AFE1302Y/2K Datasheet HTML 4Page - Texas Instruments AFE1302Y/2K Datasheet HTML 5Page - Texas Instruments AFE1302Y/2K Datasheet HTML 6Page - Texas Instruments AFE1302Y/2K Datasheet HTML 7Page - Texas Instruments AFE1302Y/2K Datasheet HTML 8Page - Texas Instruments AFE1302Y/2K Datasheet HTML 9Page - Texas Instruments AFE1302Y/2K Datasheet HTML 10Page - Texas Instruments AFE1302Y/2K Datasheet HTML 11Page - Texas Instruments  
Zoom Inzoom in Zoom Outzoom out
 7 / 11 page
background image
AFE1302
7
SBWS014
CLIP EVENT
Receive data (AFEG_RX) is generated in the AFE1302 with
additional headroom. For the one sign-bit case, if AFEG_RX
data is greater than 7FFF, it will be clipped to 7FFF.
If AFEG_RX data is less than 8000, it will be clipped to
8000. For the two sign-bit case, if AFEG_RX data is greater
than 3FFF, it will be clipped to 3FFF. If AFEG_RX data is
less than C000, it will be clipped to C000. During clip, pin
CLIP will be asserted HIGH for monitoring purposes. Pin
CLIP will remain HIGH until 0 is written to address = 010,
bit 3 in AFE1302 control register.
FIGURE 3. AFE1302 Program Timing.
CLWD
CTRLIN
CLWD
CTRLIN
Start Bit
12 Data Bits
≥ 16 HIGH Stop Bits
Data ID
3 Bit
t
S
t
H
NOTE: CLWD = 8.832MHz/N; t
S: Setup Time, min tS = 10ns; tH: Hold Time, min tH = 10ns.
PROGRAMMING THE AFE1302
The internal AFE control register, as shown in Table V, is
used to set the programmable features of the AFE1302 and to
set the VCXO frequency. Serial data is sent from the DSP to
the AFE control register on the CTRLIN pin in 16-bit blocks.
This data is clocked into the AFE1302 on the falling edge of
CLWD. AFEREG data is valid when followed by at least 16
stop bits (HIGH). The timing is shown in Figure 3. During
programming, all AFE1302 functions are active. Data ID
code 0 through 5 must be configured for normal operation;
data ID code 6 and 7 are reserved for future use.



Html Pages

1 2 3 4 5 6 7 8 9 10 11


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com