| Electronic Components Datasheet Search |
|
ST25RU3993 Datasheet(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST25RU3993 Datasheet(HTML) 13 Page - STMicroelectronics |
|
13 / 90 page ![]() DocID029764 Rev 5 13/90 ST25RU3993 Functional overview 45 The direct command Automatic Power Supply Level Setting (A2h) activates the system. To switch back to manual power supply level adjustment, the direct command Manual Power Supply Level Setting (A3h) should be sent. Before the direct command (A2h) is issued it is necessary to set and lock the PLL within the allowed target frequency (840 MHz to 960 MHz). At the beginning of the automatic adjustment, the device sets the regulators to 3.4 V and enables the RF field to simulate a normal power supply load. During the procedure the device decreases the regulated voltage in 100 mV steps, each 300 µs long. The lowest voltage that the regulator can set is 2.7 V. The procedure stops when the difference between the VEXT and the regulated voltages is at least 300 mV, or reaches the last step. The device then disables the RF field and sends an IRQ request with Irq_cmd bit (register 36h) set to high. 2.1.5 Power modes The device has four main power modes: • Power down mode • Standby mode • Normal mode – RF OFF • Normal mode – RF ON Power down mode By driving the EN pin to a logic low level the device enters the power-down mode. In this mode, the circuit is disabled. Standby mode The Standby mode is entered from normal mode by setting the option bit stby high (register 00h). In the Standby mode the voltage regulators, the reference voltage system and the crystal oscillator are operating in a low-power mode. The PLL, transmitter output stages and the receivers are switched off. All register settings are maintained while switching between Standby and Normal mode. The bias and reference voltages after stby = 0 typically stabilize within 12 ms. By then the device is ready to switch ON the RF field and start data transmission. Normal mode - RF OFF Setting the EN pin to a logic high level activates the normal mode. In this mode the following internal blocks are enabled: • All supply regulators • Reference voltage and bias system • Crystal oscillator • RF oscillator and PLL When the EN pin is set to a logic high level the bias and reference voltages become stable after 12 ms (typical value). From then on the device is ready for interaction with the internal registers. After the reference frequency source stabilizes and the CLSYS clock becomes active, the device is ready to operate according to the configuration of its internal registers. If the crystal oscillator is used, the time the crystal stabilizes depends on the crystal type used. A typical time is 1.5 ms to 3 ms. By reading the AGC and internal status display |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |