Back Button ST25RU3993 Datasheet HTML 33Page - STMicroelectronics ST25RU3993 Datasheet HTML 34Page - STMicroelectronics ST25RU3993 Datasheet HTML 35Page - STMicroelectronics ST25RU3993 Datasheet HTML 36Page - STMicroelectronics ST25RU3993 Datasheet HTML 37Page - STMicroelectronics ST25RU3993 Datasheet HTML 38Page - STMicroelectronics ST25RU3993 Datasheet HTML 39Page - STMicroelectronics ST25RU3993 Datasheet HTML 40Page - STMicroelectronics ST25RU3993 Datasheet HTML 41Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 37 / 90 page
background image
DocID029764 Rev 5
37/90
ST25RU3993
Functional overview
45
Proposed filter settings
Not all filter settings prove useful during operation. Table 8 shows proposed registers
settings, which provide optimal overall Rx filter characteristics for the supported link
frequencies and Rx coding.
Rx filter calibration
To compensate process and temperature variations of the internal resistor and of the
capacitor values, a filter calibration procedure is available. The calibration procedure is
triggered by the direct command Trigger Rx Filter Calibration (88h). The calibration is
finished after 5 ms (max.) and should be triggered after power-up, prior the first reception
and later from time to time especially if a significant temperature change has occurred.
The result of this calibration is represented by the lp_cal[3:0] and hp_cal[3:0] status bits in
the AGL/VCO/F_CAL/PilotFreq status register (r2Cpage[1:0] = 01) (2Ch) using
r2Cpage[1:0] = 10b. Typical calibration result values are 88h. The automatically calibrated
values can be adjusted by the direct commands Decrease Rx Filter Calibration Data (89h)
and Increase Rx Filter Calibration Data (8Ah), if the enabling option bit f_cal_hp_chg in the
Miscellaneous register 2 (0Eh) was set to high before.
Note that hp_cal[3:0] affects the high pass part of the filter characteristic while lp_cal[3:0]
affects the low pass part of the filter characteristic, both in 4% steps. Range is ±30%.
Table 8. Proposed Rx filter settings for supported link modes
Link Frequency
Rx Coding
Register 09h settings
DRM Modes
320 kHz
M4
24h
M8
250 kHz
M4
34h
M8
Other Supported Modes
40 kHz
FM0
FFh
M2
M4
M8
160 kHz
FM0
BFh
M2
3Fh
M4
M8
640 kHz
M4
04h
M8



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com