| Electronic Components Datasheet Search |
|
ST25RU3993 Datasheet(PDF) 20 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST25RU3993 Datasheet(HTML) 20 Page - STMicroelectronics |
|
20 / 90 page ![]() Functional overview ST25RU3993 20/90 DocID029764 Rev 5 • Direct mode (81h): device enters the direct mode. • Soft init (83h): this command resets the configuration registers to their default values and terminates all functions that were triggered before. • Hop to main frequency (84h): this command forces the PLL to use the frequency defined in the PLL Main Registers 1 - 3. The PLL main registers are used per default. • Hop to auxiliary frequency (85h): This command forces the PLL to use the frequency setting defined in the PLL auxiliary register 1, PLL auxiliary register 2 and PLL auxiliary register 3. • Trigger A/D conversion (87h): this command triggers the analog to digital conversion using the internal 8-bit A/D converter. For further information, refer to the A/D Converter description. • Trigger Rx filter calibration (88h): this command triggers the Rx filter calibration procedure. For further information, refer to the Rx filter calibration description. • Decrease Rx filter calibration data (89h), Increase Rx filter calibration data (8Ah): these commands adjust the automatically acquired Rx filter calibration data. For further information, refer to the Rx filter calibration description. • Transmission with CRC (90h): transmission commands are used to transmit data from the reader to transponders. First, the Tx length registers (3Dh, 3Eh) need to be set with the number of complete bytes for transmission, including the number of bits for the incomplete byte. Then transmission data can be loaded in the FIFO register (3Fh). Transmission starts when the first byte is loaded. CRC-16 is included in the transmitted sequence. The optimal way to load all transmission data is to use the Continuous Write mode, starting with the address 3Dh. Example Using Address Auto-Incrementing: SPI data (MOSI): 90h - 3Dh - 00h - 30h - AAh - BBh - CCh operates as follows: – 90h:Transmission with CRC – Write 00h to 3Dh – Write 30h to 3Eh (three bytes are going to be transmitted) – Write AAh, BBh, CCh to address 3Fh (FIFO data which will be transmitted). • Transmission with CRC expecting header bit (91h): same as the previous command, but it also informs Rx decoding logic that an header bit is expected in the response. • Transmission without CRC (92h): same as direct command ‘Transmission with CRC’, but the CRC part is omitted. • Block Rx (96h): the Block Rx command deactivates the digital part of receiver (bit decoder and framer). Turning OFF the receiver is useful if the system operates in a noisy environment, causing a constant switching of the sub-carrier input of the Rx digital part. The active receiver will try to detect a Preamble and if the noise pattern matches the expected signal pattern, an interrupt is generated. A constant flow of interrupt requests can be a problem for the MCU, Such situation can be avoided by deactivating the receive decoder using the Block RX command. The receiver is automatically reactivated at the end of any data transmission after the Rx wait time elapses. To set the Rx wait time refer to the Rx Wait Timer section. A second possibility to stop Block Rx is to send the Enable Rx (97h) command. • Enable Rx (97h): this command prepares analog and digital part of the receiver for reception. This command should be sent to trigger the reception manually. This |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |