5 / 16 page ![]() MOTOROLA ANALOG INTEGRATED CIRCUIT DEVICE DATA 33996 5 STATIC ELECTRICAL CHARACTERISTICS Characteristics noted under conditions 3.1 V ≤ SOPWR ≤ 5.5 V, 5.0 V ≤ VPWR ≤ 18 V, -40°C ≤ TC ≤ 125°C unless otherwise noted. Where applicable, typical values noted reflect the parameter ‘s approximate value with VPWR = 13 V, TA = 25°C. Characteristic Symbol Min Typ Max Unit POWER SUPPLY Supply Voltage Range Fully Operational VPWR(FO) 5.0 – 27 V Supply Current All Outputs ON, IOUT = 0.3 A IPWR(ON) –4.0 8.0 mA Sleep State Supply Current at RST ≤ 0.2 SOPWR and/or SOPWR ≤ 0.5 V IPWR(SS) -10 1.0 10 µA Overvoltage Shutdown VOV 27.5 31.5 35 V Overvoltage Shutdown Hysteresis VOV(HYS) 0.8 1.4 2.3 V VPWR Undervoltage Shutdown VPWR(UV) –3.2 3.5 V SPI Interface Logic Supply Voltage SOPWR 3.1–5.5 V SPI Interface Logic Supply Current (RST Pin High) ISOPWR(RSTH) 100 – 500 µA SPI Interface Logic Supply Current (RST Pin Low) ISOPWR(RSTL) -10 – 10 µA SPI Interface Logic Supply Undervoltage Lockout Threshold SOPWR(UNVOL) 2.0 2.5 3.0 V POWER OUTPUT Drain-to-Source ON Resistance (IOUT = 0.35 A, VPWR = 13 V) TJ = 125°C TJ = 25°C TJ = -40°C RDS(ON) – – – 0.75 0.55 0.45 1.2 1.2 1.2 Ω Output Self-Limiting Current Outputs Programmed ON IOUT(lim) 0.9 1.2 2.5 A Output Fault Detect Threshold (Note 11) Outputs Programmed OFF VOUTth(F) 2.5 3.0 3.5 V Output Off Open Load Detect Current (Note 12) Outputs Programmed OFF (VPWR = 5.0 V) Outputs Programmed OFF (VPWR = 13 V, 18 V) IOCO(5) IOCO(13,18) 25 30 50 50 100 100 µA Output Clamp Voltage IOUT = 20 ≤ mA VCL 45 50 55 V Output Leakage Current SOPWR ≤ 2.0 V IOUT(lkg) -10 2.0 10 µA Overtemperature Shutdown (Outputs OFF) (Note 13) TLIM 155 165 180 °C Overtemperature Shutdown Hysteresis (Note 13) TLIM(hys) 5.0 10 20 °C Notes 11. Output Fault Detect Thresholds with outputs programmed OFF. Output Fault Detect Thresholds are the same for output open and shorts. 12. Output OFF Open Load Detect Current is the current required to flow through the load for the purpose of detecting the existence of an open load condition when the specific output is commanded to be OFF. 13. This parameter is guaranteed by design but not production tested. Freescale Semiconductor, Inc. For More Information On This Product, Go to: www.freescale.com |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |