24 / 67 page ![]() CS5484 24 DS981F3 5.5.1 Pulse Rate Before configuring the PulseRate register, the full-scale pulse rate needs to be calculated and the frequency range needs to be specified through FREQ_RNG[3:0] bits in the PulseWidth register. Refer to section 6.6.6 Pulse Output Width (PulseWidth) – Page 0, Address 8 on page 41. The FREQ_RNG[3:0] bits should be set to b[0110]. For example, if a meter has the meter constant of 1000imp/kWh, a maximum voltage (UMAX) of 240 V, and a maximum current (IMAX) of 100A, the maximum pulse rate is: [1000x(240x100/1000)]/3600 = 6.6667Hz. Assume the meter is calibrated with UMAX and IMAX, and the Scale register contains the default value of 0.6. After gain calibration, the power register value will be 0.36, which represents 240x100 = 24kW or 6.6667Hz pulse output rate. The full-scale pulse rate is: Fout = 6.6667/0.36 = 18.5185Hz. The CS5484 pulse generation block behaves as follows: • The pulse rate generated by full-scale (1.0decimal) power register is: FOUT =(PulseRatex2000)/2FREQ_RNG •The PulseRate register value is: PulseRate = (FOUTx2FREQ_RNG)/2000 = (18.5186x64)/2000 = 0.5925952 = 0x4BDA29 5.5.2 Pulse Width The PulseWidth register defines the Active-low time of each energy pulse: Active-low = 250µs+(PulseWidth/64000). By default, the PulseWidth register value is 1, and the Active-low time of each energy pulse is 265.6µs. Note that the pulse width should never exceed the pulse period. 5.6 Voltage Sag, Voltage Swell, and Overcurrent Detection Voltage sag detection is used to determine when the voltage falls below a predetermined level for a specified interval of time (duration). Voltage swell and overcurrent detection determine when the voltage or current rises above a predetermined level for the duration. The duration is set by the value in the V1SagDUR (V2SagDUR), V1SwellDUR (V2SwellDUR), and I1OverDUR (I2OverDUR) registers. Setting any of these to zero (default) disables the detect feature for the given channel. The value is in output word rate (OWR) samples. The predetermined level is set by the values in the V1SagLEVEL (V2SagLEVEL), V1SwellDUR (V2SwellDUR), and I1OverLEVEL (I2OverLEVEL) registers. For each enabled input channel, the measured value is rectified and compared to the associated level register. Over the duration window, the number of samples above and below the level are counted. If the number of samples below the level exceeds the number of samples above, a Status0 register bit V1SAG (V2SAG) is set, indicating a sag condition. If the number of samples above the level exceeds the number of samples below, a Status0 register bit V1SWELL (V2SWELL) or I1OVER (I2OVER) is set, indicating a swell or overcurrent condition (see Figure 15). Lev el Du ra tio n Figure 15. Sag, Swell, and Overcurrent Detect |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |