| Electronic Components Datasheet Search |
|
DSP56857 Datasheet(PDF) 290 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
DSP56857 Datasheet(HTML) 290 Page - Freescale Semiconductor, Inc |
|
290 / 662 page ![]() Error Conditions 5685X Digital Signal Controller User Manual, Rev. 4 11-20 Freescale Semiconductor In a Master SPI with the Mode Fault Enable (MODFEN) bit set, the Mode Fault (MODF) flag is set if SS goes to Logic 0. A Mode Fault in a Master SPI causes the following events to occur: • If ERRIE = 1, the SPI generates a SPI receiver/error interrupt request • The SPE bit is cleared (SPI disabled) • The SPTE bit is set • The SPI state counter is cleared When configured as a slave (SPMSTR = 0), the MODF flag is set if the SS goes high during a transmission. When CPHA = 0, a transmission begins when SS goes low and ends once the incoming SCLK goes back to its idle level, following the shift of the last data bit. When CPHA = 1, the transmission begins when the SCLK leaves its idle level and SS is already low. The transmission continues until the SCLK returns to its idle level following the shift of the last data bit. Note: Setting the MODF flag does not clear the SPMSTR bit. The SPMSTR bit has no function when SPE = 0. Reading SPMSTR when MODF = 1 shows the difference between a MODF occurring when the SPI is a master and when it is a slave. When CPHA = 0, a MODF occurs if a slave is selected (SS is at Logic 0) and later unselected (SS is at Logic 1) even if no SCLK is sent to that slave. This happens because SS at Logic 0 indicates the start of the transmission (MISO driven out with the value of MSB) for CPHA = 0. When CPHA = 1, a slave can be selected and then later unselected with no transmission occurring. Therefore, MODF does not occur since a transmission was never begun. In a Slave SPI (MSTR = 0), the MODF bit generates a SPI Receiver/Error Interrupt request if the ERRIE bit is set. The MODF bit does not clear the SPE bit or reset the SPI in any way. Software can abort the SPI transmission by clearing the SPE bit of the slave. Note: A logic one voltage on the SS pin of a slave SPI puts the MISO pin in a high impedance state. Also, the slave SPI ignores all incoming SCLK clocks, even if it was already in the middle of a transmission. In a master SPI, the MODF flag will not be cleared until the SS pin is at a Logic 1 or the SPI is configured as a slave. In a slave SPI, if the MODF flag is not cleared by writing 1 to the MODF bit, the condition causing the Mode Fault still exists. The MODF flag and corresponding interrupt can be cleared by disabling the EERIE or MODFEN bits (if set) or by disabling the SPI. It is possible to clear the MODF error condition by disabling the SPE or MODFEN bits. Disabling the SPI using the SPE bit will cause a partial reset of the SPI and may cause the loss of a message currently being received or transmitted. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |