| Electronic Components Datasheet Search |
|
TLE5014 Datasheet(PDF) 25 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLE5014 Datasheet(HTML) 25 Page - Infineon Technologies AG |
|
25 / 45 page ![]() Final Datasheet 25 Rev. 1.0 2018-04-04 TLE5014 Interfaces PWM Interface Error Indication For diagnostic purpose and to indicate internal sensor failures, the output duty cycle of the PWM is limited. Within this reserved lower and upper duty cycle range, no valid angle information is provided. Instead, this duty cycle range is used for error indication with defined duty cycles which are clearly separated from the usable data duty cycle range. The following events are indicated: • Error occurred during performing the built-in self test (BIST) after power-up • Occurrence of internal or external fault • Sensor reset occurred PWM Interface Configuration The PWM interface parameter can be configured in a wide range. Beside the frequency, it is also possible to define data duty cycle range and low and high value of the diagnostic duty cycle. It has to be ensured by proper device configuration that there is no overlap of data duty cycle range and low or high value of diagnostic duty cycle. A possible and valid configuration is: • Data duty cycle: 12.5% ...87.5%, the 12bit angle value is mapped to this duty cycle • Diagnostic duty cycle, low: 5%; an internal sensor fault is indicated with this duty cycle • Diagnostic duty cycle, high: 95%; an start-up BIST error or sensor reset is indicated with this duty cycle TPWM = 1/fPWM Reserved duty cycle range for diagnostics PWM out t Duty cycle range for angle value transmission The PWM interface with data duty cycle range and reserved duty cycle for diagnostics is shown in Figure 4-1 Figure 4-1 PWM interface with duty cycle range starting with a rising edge As the PWM interface is an analog protocol, the rise and fall times, as well as the trigger level for the detection of the high and low state of the signal have influence on the measured duty cycle. Therefore, an additional angle error is introduced which varies with the measurement conditions (e.g. Rp, CW, trigger level). This error contribution is not included in Table 3-11 and Table 3-12. Table 4-2 PWM Frequency tolerance Parameter Symbol Values Unit Note / Test Condition Min. Typ. Max. PWM Frequency tolerance PWMfreq_tol -5 5 % |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |