| Electronic Components Datasheet Search |
|
ICL7135C/D Datasheet(PDF) 6 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
ICL7135C/D Datasheet(HTML) 6 Page - Maxim Integrated Products |
|
6 / 13 page ![]() the rising edge of the RUN/HOLD input and the BUSY output. A RUN/HOLD pulse during the unused portion of deintegrate phase will be ignored, but when in the auto- zero phase a positive pulse of only 300ns (typical) will start the conversion. Figure 5 shows a simple method of obtaining one, and only one, conversion for each measurement request. BUSY BUSY is a status output that goes high at the beginning of signal integrate and stays high until the first clock pulse after zero crossing during De-integrate (or end of De-Integrate if overranged).The internal data latches are loaded during the next clock cycle after the falling edge of BUSY. Since BUSY is high for the 10,000 counts of signal integrate + number of counts during De-Integrate +1 clock cycle, a simple way of sending conversion data down a single pair of wires is to logically ‘AND’ BUSY with the clock and to subtract 10,001 counts from the number received. Figure 6 shows a system using this method to remotely display data. Figure 3. ICL7135 Digital Section Figure 4. Timing Diagram Figure 5. External RUN/HOLD Latch ICL7135 41/2 Digit A/D Converter with Multiplexed BCD Outputs www.maximintegrated.com Maxim Integrated │ 6 MSB POLARITY FF ANALOG SECTION ZERO CROSS. DET. 24 22 25 27 28 26 21 DIGITAL GND CLOCK IN OVER RANGE UNDER RANGE BUSY CONTROL LOGIC MULTIPLEXER COUNTERS LATCH LATCH LATCH LATCH LATCH STROBE RUN/ HOLD LSB 13 14 15 16 B1 B2 B4 B8 12 11 23 D5 V+ POLARITY 17 D4 18 D3 19 D2 20 D1 ICL7135 INTEGRATOR OUTPUT BUSY OVER-RANGE WHEN APPLICABLE UNDER-RANGE WHEN APPLICABLE NORMAL DIGIT SCAN 1000* COUNTS AUTO ZERO DIGIT SCAN FOR OVER-RANGE *FIRST D5 OF AZ AND DE-INTEGRATE ARE ONE COUNT LONGER DE-INTEGRATE SIGNAL INTEGRATE *STROBE D5 D4 D3 D2 D1 D5 D4 D3 D2 D1 AUTO- ZERO + ZERO INTEGRATOR 10,0001 COUNTS SIGNAL INT. 10,000 COUNTS FULL MEASUREMENT CYCLE 40,002 COUNTS DE-INTEGRATE 20,001 COUNTS MAX. RUN/HOLD FLIP-FLOP START PULSE Q D R D S ICL7135 BUSY |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |