33 / 48 page ![]() DocID028118 Rev 5 33/48 VNH7040AY Open Load detection in off-state 47 7 Open Load detection in off-state The Open Load (OL) detection in off-state operates when output is deactivated (it means INA = INB = PWM = 0). Open load detection is performed by reading the MultiSense output. External (switched) pull-up resistor has to be used and dimensioned to pull output voltage above the maximum open load detection voltage (VOL MAX) when load is not connected. Possible conditions are specified in Table 14. If pull up resistor is applied over switched circuitry, it allows to detect short to VCC from Open load. Depending on application setup, two cases can be applied: Half-bridge, with separate loads on OUTA and OUTB, open-load pull-up resistor RPU is applied for each side; see example in the figure below. Figure 19. Open load detection in off-state - configuration two half-bridges if the device is used in half bridge configuration, the RPU value has to be: Rpull_up VBATTmin VOLmax – ILoff2 min @VOLmax ------------------------------------------------------- Full bridge (load connected between OUTA and OUTB), only one pull-up resistor RPU is sufficient; see example in the figure below. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |