19 / 30 page ![]() 2020 Microchip Technology Inc. DS20006433A-page 19 UCS3205 4.13 Fault Handling A Fault state means that at least one of the following conditions has occurred: • Short Circuit (SC signal), • Overcurrent (OC signal), • Overvoltage (OV signal), • Thermal Shutdown (TSD signal), or • Back-Voltage (BV signal) – Fault DOES NOT apply when the Power Switch is off (EN = 0). When the Fault state is detected, the digital logic turns off the switch and asserts the FAULT# pin. At the time when the Fault is detected, the UCS3205 discharges the output for the duration of tDISCHARGE. If the LATCH pin is VIH at the time when the Fault is detected, the digital logic remains in the Fault state until the EN pin is toggled low-to-high, the Fault conditions are no longer present (OV, TSD, BV) and the Fault recovery procedure begins. If the LATCH pin is VIL at the time when the Fault is detected, the UCS3205 subsequently enters Auto-Retry mode, where it runs the Fault recovery procedure every tRETRY, until no Fault condition (Overvoltage [OV signal], Thermal Shutdown [TSD signal], Back-Voltage [BV signal if DIR = 0]) is detected or until the EN pin is pulled low. Figure 4-5 shows the Auto-Retry mode (LATCH pulled low) Fault recovery timing in the case of a short circuit. At the end of the Fault recovery procedure, if none of the Fault conditions are met, the FAULT# pin is deasserted and the power switch is turned on. FIGURE 4-5: Auto-Retry Mode Fault Recovery Timing – Short-Circuit Case. VOUT IOUT Short applied. tDISCHARGE VTST Check short condition. Short still present. FAULT# state maintained. Wait tRETRY. 400 µs tRETRY FAULT # Short detected. VOUT discharged. Enter Fault state. - Short Circuit (SC signal) – t MASK does NOT apply - Thermal Shutdown (TSD signal) – t MASK does NOT apply - Back-Voltage (BV signal) – t MASK does NOT apply - Overvoltage (OV signal ) – t MASK does NOT apply - Overcurrent (OC signal) – t MASK implemented SW_EN ON OFF ON OFF tREADY 400 µs Check short condition. Short removed. Return to normal operation. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |