Back Button S25FL040A0LMAI011 Datasheet HTML 10Page - SPANSION S25FL040A0LMAI011 Datasheet HTML 11Page - SPANSION S25FL040A0LMAI011 Datasheet HTML 12Page - SPANSION S25FL040A0LMAI011 Datasheet HTML 13Page - SPANSION S25FL040A0LMAI011 Datasheet HTML 14Page - SPANSION S25FL040A0LMAI011 Datasheet HTML 15Page - SPANSION S25FL040A0LMAI011 Datasheet HTML 16Page - SPANSION S25FL040A0LMAI011 Datasheet HTML 17Page - SPANSION S25FL040A0LMAI011 Datasheet HTML 18Page - SPANSION Next Button
Zoom Inzoom in Zoom Outzoom out
 14 / 35 page
background image
12
S25FL040A
S25FL040A_00_B0 August 31, 2006
Data
Sheet
(Pre limin ar y)
7.7
Hold Mode (HOLD#)
The Hold input (HOLD#) stops any serial communication with the device, but does not terminate any Write
Status Register, program or erase operation that is currently in progress.
The Hold mode starts on the falling edge of HOLD# if SCK is also low (see Figure 7.1, on page 12, standard
use). If the falling edge of HOLD# does not occur while SCK is low, the Hold mode begins after the next falling
edge of SCK (non-standard use).
The Hold mode ends on the rising edge of HOLD# signal (standard use) if SCK is also low. If the rising edge
of HOLD# does not occur while SCK is low, the Hold mode ends on the next falling edge of CLK (non-
standard use) See Figure 7.1.
The SO output is high impedance, and the SI and SCK inputs are ignored (don’t care) for the duration of the
Hold mode.
CS# must remain low for the entire duration of the Hold mode to ensure that the device internal logic remains
unchanged. If CS# goes high while the device is in the Hold mode, the internal logic is reset. To prevent the
device from reverting to the Hold mode when device communication is resumed, HOLD# must be held high,
followed by driving CS# low.
Figure 7.1 Hold Mode Operation
Table 7.3 S25FL040A Protected Area Sizes (Uniform Sector)
Status Register
Block Protect Bits
Memory Array
Protected Portion of
Total Memory Area
BP2
BP1
BP0
Protected
Address Range
Protected
Sectors
Unprotected
Address Range
Unprotected
Sectors
0
0
0
None
(0)
00000–7FFFF
SA7:SA0
0
0
0
1
70000–7FFFF
(1) SA7
00000–6FFFF
SA6:SA0
Upper 1/8 (64 KB)
0
1
0
60000–7FFFF
(2) SA7:SA6
00000–5FFFF
SA5:SA0
Lower 1/4 (128 KB)
0
1
1
40000–7FFFF
(4) SA7:SA4
00000–3FFFF
SA3:SA0
Lower 1/2 (256 KB)
1
0
0
00000–7FFFF
(8) SA7:SA0
None
None
All (512 KB)
1
0
1
00000–7FFFF
(8) SA7:SA0
None
None
All (512 KB)
1
1
0
00000–7FFFF
(8) SA7:SA0
None
None
All (512 KB)
1
1
1
00000–7FFFF
(8) SA7:SA0
None
None
All (512 KB)
SCK
HOLD#
Hold
Condition
(standard use)
Hold
Condition
(non-standard use)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com