14 / 35 page ![]() 12 S25FL040A S25FL040A_00_B0 August 31, 2006 Data Sheet (Pre limin ar y) 7.7 Hold Mode (HOLD#) The Hold input (HOLD#) stops any serial communication with the device, but does not terminate any Write Status Register, program or erase operation that is currently in progress. The Hold mode starts on the falling edge of HOLD# if SCK is also low (see Figure 7.1, on page 12, standard use). If the falling edge of HOLD# does not occur while SCK is low, the Hold mode begins after the next falling edge of SCK (non-standard use). The Hold mode ends on the rising edge of HOLD# signal (standard use) if SCK is also low. If the rising edge of HOLD# does not occur while SCK is low, the Hold mode ends on the next falling edge of CLK (non- standard use) See Figure 7.1. The SO output is high impedance, and the SI and SCK inputs are ignored (don’t care) for the duration of the Hold mode. CS# must remain low for the entire duration of the Hold mode to ensure that the device internal logic remains unchanged. If CS# goes high while the device is in the Hold mode, the internal logic is reset. To prevent the device from reverting to the Hold mode when device communication is resumed, HOLD# must be held high, followed by driving CS# low. Figure 7.1 Hold Mode Operation Table 7.3 S25FL040A Protected Area Sizes (Uniform Sector) Status Register Block Protect Bits Memory Array Protected Portion of Total Memory Area BP2 BP1 BP0 Protected Address Range Protected Sectors Unprotected Address Range Unprotected Sectors 0 0 0 None (0) 00000–7FFFF SA7:SA0 0 0 0 1 70000–7FFFF (1) SA7 00000–6FFFF SA6:SA0 Upper 1/8 (64 KB) 0 1 0 60000–7FFFF (2) SA7:SA6 00000–5FFFF SA5:SA0 Lower 1/4 (128 KB) 0 1 1 40000–7FFFF (4) SA7:SA4 00000–3FFFF SA3:SA0 Lower 1/2 (256 KB) 1 0 0 00000–7FFFF (8) SA7:SA0 None None All (512 KB) 1 0 1 00000–7FFFF (8) SA7:SA0 None None All (512 KB) 1 1 0 00000–7FFFF (8) SA7:SA0 None None All (512 KB) 1 1 1 00000–7FFFF (8) SA7:SA0 None None All (512 KB) SCK HOLD# Hold Condition (standard use) Hold Condition (non-standard use) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |