17 / 35 page ![]() August 31, 2006 S25FL040A_00_B0 S25FL040A 15 Da ta Shee t (Prelim i nar y ) Figure 9.1 Read Data Bytes (READ) Command Sequence 9.2 Read Data Bytes at Higher Speed (FAST_READ) The FAST_READ command reads data from the memory array at the frequency (fSCK) presented at the SCK input, with a maximum speed of 50 MHz. The host system must first select the device by driving CS# low. The FAST_READ command is then written to SI, followed by a 3-byte address (A23-A0) and a dummy byte. Each bit is latched on the rising edge of SCK. The memory array data, at that address, are output serially on SO at a frequency fSCK, on the falling edge of SCK. The FAST_READ command sequence is shown in Figure 9.2 and Table 9.5. The first byte specified can be at any location. The device automatically increments to the next higher address after each byte of data is output. The entire memory array can therefore be read with a single FAST_READ command. When the highest address is reached, the address counter reverts to 00000h, allowing the read sequence to continue indefinitely. The FAST_READ command is terminated by driving CS# high at any time during data output. The device rejects any FAST_READ command issued while it is executing a program, erase, or Write Status Register operation, and continues the operation uninterrupted. Figure 9.2 Read Data Bytes at Higher Speed (FAST_READ) Command Sequence 9.3 Read Identification (RDID) The Read Identification (RDID) command outputs the one-byte manufacturer identification, followed by the two-byte device identification, to the host system. JEDEC assigns the manufacturer identification byte; for Spansion devices it is 01h. The device manufacturer assigns the device identification: the first byte provides the memory type; the second byte indicates the memory capacity. See Table 9.1 or Table 9.5 for device ID data. The host system must first select the device by driving CS# low. The RDID command is then written to SI, and each bit is latched on the rising edge of SCK. The 24-bit device identification data is output from the memory array on SO at a frequency fSCK, on the falling edge of SCK. Command 24-Bit Address Hi-Z MSB MSB Data Out 1 Data Out 2 0 31 32 33 34 35 36 37 38 39 30 29 28 10 9 8 7 6 5 4 3 2 1 7 6 5 23 22 21 4 3 2 1 0 3 2 10 7 SO SI SCK CS# Mode 3 Mode 0 CS# SCK SI SO Command 24-Bit Address Dummy Byte Hi-Z DATA OUT 1 DATA OUT 2 MSB MSB 01 2 3 4 56 7 8 9 10 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 23 22 21 3 2 1 0 7 65 4 3 2 1 0 7 6 5 4 3 21 0 7 Mode 3 Mode 0 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |