21 / 36 page ![]() ILED = ILED_FS u ZoneTarget0 = 25 mA u 0.336% | 84 PA. Ambient Light (lux) Vals_ref = 1V ZB3 ZB0 ZB1 ZB2 Zone 0 Zone 4 Zone 3 Zone 2 Zone 1 LED Driver Input Code (0-127) Full Scale Z0T Z4T Z3T Z2T Z1T 21 LM3535 www.ti.com SNVS598B – AUGUST 2010 – REVISED MARCH 2018 Product Folder Links: LM3535 Submit Documentation Feedback Copyright © 2010–2018, Texas Instruments Incorporated Zone Boundary 0 = 200 mV Zone Boundary 1 = 400 mV Zone Boundary 2 = 600 mV Zone Boundary 3 = 800 mV These Zone Boundary Registers are all 8-bit (readable and writable) registers. By default, the first zone (Z0) is defined between 0 and 200 mV, default for Z1 is defined between 200 mV and 400 mV, Z2 is defined between 400 mV and 600 mV, Z3 is defined between 600 mV and 800 mV, and Z4 is defined between 800 mV and 1 V. The default settings for the 5 Zone Target Registers are 0x19, 0x33, 0x4C, 0x66, and 0x7F. This corresponds to LED brightness settings of 84 µA, 164 µA, 1.45 mA, 6.17 mA and 25 mA of current, respectively. See Figure 31. Figure 31. ALS Zone to LED Brightness Mapping 8.2.2.1.2.1 ALS Configuration Example As an example, assume that the APDS-9005 is used as the ambient light sensing photo diode with its output connected to the ALS input. The ALS Resistor Select Register (Address 0x51) is loaded with 0x40 which configures the ALS input for a 2.32-k Ω internal pulldown resistor (see Table 2). This gives the output of the APDS-9005 a typical voltage swing of 0 to 875mV with a 0 to 1k LUX change in ambient light (0.875mV/Lux). Next, the Configuration Register (Address 0x20) is programmed with 0xDC, the ALS Control Register (Address 0x50) programmed to 0x40 and the Control Register is programmed to 0x3F . This configures the device ALS interface for: • Ambient Light Current Control for BankA enabled • ALS circuitry enabled • Assigns D53 and D62 to bankA • Sets the ALS Averaging Time to 400 ms Next, the Control Register (Address 0x10) is programmed with 0x3F which enables the 6 LEDs via the I2C- compatible interface. Now assume that the APDS-9005 ambient light sensor detects a 100 LUX ambient light at its input. This forces the ambient light sensor output (and the ALS input) to 87.5 mV corresponding to Zone 0. Since Zone 0 points to the brightness code programmed in Zone Target Register 0 (loaded with code 0x19), the LED current becomes: (2) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |