Back Button SH79F1615P/032PR Datasheet HTML 60Page - SINOWEALTH Electronic Ltd SH79F1615P/032PR Datasheet HTML 61Page - SINOWEALTH Electronic Ltd SH79F1615P/032PR Datasheet HTML 62Page - SINOWEALTH Electronic Ltd SH79F1615P/032PR Datasheet HTML 63Page - SINOWEALTH Electronic Ltd SH79F1615P/032PR Datasheet HTML 64Page - SINOWEALTH Electronic Ltd SH79F1615P/032PR Datasheet HTML 65Page - SINOWEALTH Electronic Ltd SH79F1615P/032PR Datasheet HTML 66Page - SINOWEALTH Electronic Ltd SH79F1615P/032PR Datasheet HTML 67Page - SINOWEALTH Electronic Ltd SH79F1615P/032PR Datasheet HTML 68Page - SINOWEALTH Electronic Ltd Next Button
Zoom Inzoom in Zoom Outzoom out
 64 / 144 page
background image
SH79F1615
64
Table 8.21 PWM0/1/2故障检测保护寄存器
D1H
第7位
第6位
第5位
第4位
第3位
第2位
第1位
第0位
FLTCON
FLT1EN
FLT1SEL
FLT2EN
FLT2S
FLT2DEB1 FLT2DEB0
FLTM
FLTSTAT
读/写
读/写
读/写
读/写
读/写
读/写
读/写
读/写
读/写
复位值
(POR/WDT/LVR/PIN)
0
0
0
0
0
0
0
0
位编号
位符号
说明
7
FLT1EN
故障检测1功能控制位(注1)
0:故障检测1功能禁止
1:故障检测1功能打开,输入源可以选择比较器1或比较器2
6
FLT1SEL
故障检测1输入源选择控制位
0:比较器1滤波后的输出作为PWM故障检测1输入源,高电平有效
1:比较器2滤波后的输出作为PWM故障检测1输入源,高电平有效
5
FLT2EN
故障检测2功能控制位(注1)
0:故障检测2功能禁止
1:故障检测2功能打开,输入源为FLT引脚
4
FLT2S
故障检测2有效电平选择位
0:故障检测2 FLT输入高电平有效
1:故障检测2 FLT输入低电平有效
3 - 2
FLT2DEB[1:0]
故障检测2输入滤波参数选择
00:无滤波
01:滤波时间常数为1us
10:滤波时间常数为4us
11:滤波时间常数为16us
注:上述滤波常数时间不是精确值,仅供参考
1
FLTM
检测功能模式选择
0:锁存模式,当检测到故障输入有效,FLTSTAT 被硬件置1,PWM将立即停止
输出,当故障输入变为无效时状态保持不变,只有当FLTSTAT被软件清零后,
PWM波形才会在PWM时基计数器归0时刻恢复输出。(当故障输入一直有效
时FLTSTAT无法被软件清除)
1:逐次模式,PWM输出直接由故障检测输入端来控制,如果故障输入有效,
FLTSTAT被硬件置1,
立即关闭PWM输出。如果故障输入变为无效,FLTSTAT
自动清0,PWM0/1/2波形将在PWM时基计数器归0时刻自动恢复输出
0
FLTSTAT
故障检测标志位
0:PWM0/1/2模块处于正常输出状态
1:出现过流,PWM0/1/2模块处于停止输出状态,如果在锁存模式,
可软件清0,恢复PWM输出
注1:故障检测输入1和2可同时打开,任一信号有效都会关闭PWM0/1/2模块输出。



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com