48 / 199 page ![]() ams Datasheet Page 47 [v1-01] 2015-Sep-07 Document Feedback AS3722 − Detailed Descriptions- Power Management Functions Parameter Figure 47: Backup-Battery Charger Parameter Backup-Battery Charger Parameter: Shows the key electrical parameter of the charger for the backup battery Symbol Parameter Conditions Min Typ Max Unit VSUP Supply voltage range BBCVolt=’0’ 3.0 5.5 V BBCVolt=’1’ 3.3 5.5 VBBC Maximum charging voltage BBCVolt=’0’ 2.4 2.5 2.6 V BBCVolt=’1’ 2.9 3.0 3.1 IBBC Charge current Value is set by BBCCur in the Backup Battery Charger register -30% BBCCur +30% A VDELTA Delta voltage for resistive mode BBCResOff=’0’ 160 220 300 mV IVSUP Supply current BBCResOff=’0’ 20 μA BBCResOff=’1’ BBCPwrSave=’1’; backup battery full. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|