| Electronic Components Datasheet Search |
|
AS3722 Datasheet(PDF) 60 Page - ams-OSRAM AG |
|
|
|||||||||||||||||||||||||||||
AS3722 Datasheet(HTML) 60 Page - ams-OSRAM AG |
|
60 / 199 page ![]() ams Datasheet Page 59 [v1-01] 2015-Sep-07 Document Feedback AS3722 − Detailed Descriptions- System Functions Figure 57: Stand-By State Description Enter via ENABLE1 To enter stand-by mode the following settings have to be done: • Enable just these IRQ sources which should lead to leave stand-by mode. • Make sure that IRQ is inactive (IRQ flags get cleared by register reading) • Enable ENABLE1 (enable1_deepsleep=1) • Set regX_select_stby to define the sequence for going into stand-by for up to 10 regulators • Set regX_voltage_stby if another voltage is needing during stand-by • Define which regulators should be kept powered during stand-by (sdX_stby_on and ldoX_stby_on) • Define the delay between the regulators when going into stand-by (regX_delay_stdby and delay_time_stby) • Activate ENABLE1 (pull LOW) Enter via GPIO To enter stand-by mode the following settings have to be done: • Enable just these IRQ sources which should lead to leave stand-by mode. • Make sure that IRQ is inactive (IRQ flags get cleared by register reading) • Set the GPIO to input (gpioX_mode = 0) • Set the GPIO for stand-by control (gpioX_iosf = 5) • Set regX_select_stby to define the sequence for going into stand-by for up to 10 regulators • Set regX_voltage_stby if another voltage is needing during stand-by • Define the regulators to be controlled by a specific GPIO (gpio_ctrl_sdX and gpio_ctrl_ldoX) • Define which regulators should be kept powered during stand-by (sdX_stby_on and ldoX_stby_on) • Define the delay between the regulators when going into stand-by (regX_delay_stdby and delay_time_stby) • Set the delay for going into stand-by after GPIO activation (off_delay) • Activate the selected GPIO (set to HIGH) Enter via SW To enter stand-by mode the following settings have to be done: • Enable just these IRQ sources which should lead to leave stand-by mode. • Make sure that IRQ is inactive (IRQ flags get cleared by register reading) • Set regX_select_stby and regX_voltage_stby if another voltage is needing during stand-by for up to 10 regulators • Define which regulators should be kept powered during stand-by (sdX_stby_on and ldoX_stby_on) • Set the delay for going into stand-by after the SW command (off_delay) • set standby_mode_on to 1 Stand-by V2_5 chip supply is kept ON All other regulators are switched OFF dependent on the bits sdX_stby_on and ldoX_stby_on XRES_OUT goes active (can be disabled with stdby_reset_disable) and pwr_good goes inactive |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |