| Electronic Components Datasheet Search |
|
CS-LD03 Datasheet(PDF) 1 Page - Wavelength Electronics, Inc. |
|
|
|||||||||||||||||||||||||||||
CS-LD03 Datasheet(HTML) 1 Page - Wavelength Electronics, Inc. |
|
1 / 5 page ![]() © 2021 • Sales & Technical Support: (406) 587-4910 • email: sales@teamWavelength.com • web: www.teamWavelength.com Case Study CS-LD03 Rev. A Optical Interruption of Quantum Cascade Laser for Cavity Ring- Down Spectroscopy January, 2021 Page 1 ABSTRACT Researchers from VTT Technical Research Centre of Finland have developed optical interruption of a mid- infrared (MIR) quantum cascade laser (QCL) using a near-infrared (NIR) laser diode for cavity ring-down spectroscopy (CRDS). The QCL is modulated from the injection of the NIR laser diode, and this shifts the frequency of the signal in the cavity generating rapid interruption of the high-finesse cavity resonance. This method is compared to the traditional electrical interruption method and shows similar performance. Optical interruption reduces the high bandwidth requirements of the QCL driver as well as lowers cost and complexity of the system. The necessary precision control was provided by Wavelength Electronics' laser and QCL drivers. With this optical interruption method, other potential applications in MIR laser spectroscopy are now possible. CRDS BACKGROUND Cavity Ring-Down Spectroscopy (CRDS) is one of the most sensitive laser spectroscopy methods. It is effective at detecting a variety of molecules at trace concentrations. CRDS is based on the amount of time it takes the laser beam to decay in a high finesse resonator made up of high reflectivity mirrors. This multi-pass cavity allows the effective distance traveled by the light to increase to lengths as long as a few kilometers. Longer distance traveled through a sample gas ensures better measurement precision. When the light into the cavity is interrupted, a ring-down event is started ( Figure 1), and the decay time can be accurately measured. A detector is used after the cavity to ensure the correct threshold of light build-up in the cavity has occurred, and it can measure the light leakage out of the cavity (mirrors are not 100% reflective) to track the time decay once the light has been interrupted.1 CRDS allows spectroscopy measurements independent of laser power stability. Because the laser light into the cavity is interrupted when enough light has built-up in the cavity, the concern is no longer the laser itself but the decay time of the light in the resonator. The decay time of the light varies with the specific molecules trapped in the cavity. The absorption coefficient of certain molecules can be found by comparing the cavity ring-down (CRD) time when those molecules are in the cavity with the CRD time of an empty cavity. Different molecules will have unique absorption coefficients and spectra. The CRD time will be accelerated with absorbing gas inside the cavity and will only be affected by the reflectivity of the mirrors and the absorbing substance inside the cavity.1 For trace concentration measurements, accurate calibration with an empty cavity is essential. CRDS applications include atmospheric sensing, Mirror Mirror Cavity Laser Input Empty Cavity Ring-Down Decay Time after interruption Gas-Filled Cavity Ring-Down Decay industrial monitoring, air quality monitoring, detection of harmful compounds, and medical applications among others. Figure 1. Cavity Ring-Down Spectroscopy Schematic It is common for researchers to use infrared (IR) lasers for spectroscopy applications. Mid-infrared (MIR), ranging from 3 - 50 µm, consists of the best absorption transitions, specifically fundamental rotational and vibrational transitions, of many important molecules. Compared to near-infrared (NIR) and far-infrared (FIR), MIR has a cleaner spectrum with more distinct peaks and troughs for the specified absorbed sample. MIR enables trace detection in small volumes of homogeneous samples, unlike NIR and FIR. Some gases have weak transitions in NIR but are much stronger in the MIR region. CRDS utilizes the strong absorption coefficients in the MIR range for more sensitive measurements. |
Similar Part No. - CS-LD03 |
|
Similar Description - CS-LD03 |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |