| Electronic Components Datasheet Search |
|
CS-LD12 Datasheet(PDF) 3 Page - Wavelength Electronics, Inc. |
|
|
|||||||||||||||||||||||||||||
CS-LD12 Datasheet(HTML) 3 Page - Wavelength Electronics, Inc. |
|
3 / 5 page ![]() Case Study CS-LD12 Rev. A Page 3 © 2024 • Sales & Technical Support: (406) 587-4910 • email: sales@teamWavelength.com • web: www.teamWavelength.com Once the LICF system was validated and calibrated with known concentrations of chlorophyll in palm oil samples, operational testing began. Palm oil samples were introduced into a transparent flow cell where the sensing system continuously monitored chlorophyll levels. To keep the main DCO pipe uninterrupted, a secondary pipe was installed with this transparent flow cell. The system demonstrates the capability to provide real-time feedback on oil quality by correlating chlorophyll concentration with fruit maturity. The monitoring location in Figure 4 also tested the system's ability to excite the chlorophyll and collect data even with extra fibers from the fruit and soil obstructing the light distribution and absorption. Samples used for the LICF probe were split into two portions: one stayed at the palm oil mill for chlorophyll measurements, and the other portion was sent to the AOCS for validation. The measurement accuracy was validated by comparing sensor data with the AOCS laboratory analyses of oil samples. The system was able to detect chlorophyll concentration variations with high precision, confirming its reliability for real-time quality monitoring. All results were averaged over multiple measurements to enhance the signal-to-noise ratio and ensure data consistency. RESULTS The results revealed a significant correlation between chlorophyll photo-response and key quality indicators. For instance, a decrease in chlorophyll concentration was observed in palm oil with a longer wait time after pollination, a more mature fruit. The system effectively provided real- time alerts for deviations in quality parameters, allowing for timely adjustments in the milling process. Figure 4. Flow chart of oil palm fresh fruit bunches (FFB) processing at palm oil mills and in-line Chlorophyll LICF prototype setup implemented at dilution & oil classification point in Malaysia. (i) The DCO, after pulp pressing, will flow through the main pipe to the holding tank. A secondary pipe is installed under the main pipe for the installation of the LICF probe. (ii) LICF probe being held by a Teflon probe holder. The probe is separated from the DCO via a sapphire window. The Teflon probe holder is designed to have an opening to enable visual inspection of DCO flow.1 With the light-induced chlorophyll fluorescence design, researchers were able to leverage the natural response of chlorophyll to assess the quality of the palm oil. Measurements were analyzed for fruit collected at different weeks after pollination for real-time, non-invasive monitoring of the palm oil quality before refinement in Figure 5. Figure 5. (a) LICF chlorophyll fluorescence spectra of CPO of FFB from different weeks after pollination. (b) Fluorescence area plot vs weeks after pollination.1 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |