4 / 5 page ![]() Case Study CS-LD12 Rev. A Page 4 © 2024 • Sales & Technical Support: (406) 587-4910 • email: sales@teamWavelength.com • web: www.teamWavelength.com Real-time monitoring data, shown in Figure 6, demonstrated that the system effectively provided feedback on palm oil quality. The system’s ability to detect changes in chlorophyll concentration allowed for timely adjustments to the milling process, enhancing process efficiency and quality control. Real-time monitoring also provided instant feedback on flow parameters, mill operation timings, hot water flushing, and the rapidly changing oil quality. Figure 6. LICF operational plot for 2 days of mill run. PT1, PT2, and PT4 indicate the point in time of hot water pipeline flushing, DCO flows, and end-of-mill operation, respectively. PT3 highlights the point when a high chlorophyll level is being observed. Inset graph plots out the chlorophyll fluorescence at PT1, PT2, and PT3.1 Samples of DCO were collected and measured for chlorophyll levels and compared with AOCS measurements. Although these samples are not real-time, there was still a very strong correlation coefficient of 0.90 between the LICF's measurements and AOCS results. Figure 7 shows the real-time, in-line palm oil mill samples comparison between the LICF prototype's signal and the AOCS data measured in the laboratory. The correlation between the chlorophyll sensor measurements and AOCS results was still very strong, with a correlation coefficient of 0.88.1 This high accuracy confirms the effectiveness of the in-line sensing system for real-time monitoring of palm oil quality. With the LICF design communicating with a computer in the mill, approximately 1320 spectra can be collected per day, allowing production line workers to adjust the palm fruit used based on maturity levels from chlorophyll measurements. Multiple tests across different stages of the milling process showed consistent results, indicating that the system is well-suited for continuous quality assessment. The average chlorophyll concentration changes were observable with varying quality indicators, demonstrating the system’s capability to adapt to different process conditions. Overall, the developed LICF system provides a reliable and efficient method for real-time, non-invasive monitoring of palm oil quality. The accuracy and repeatability of chlorophyll measurements and the system’s integration into the milling process offer significant improvements in quality control and process optimization for palm oil processing or other applications where chlorophyll can be measured. Figure 7. Comparison between the online LICF signal and the AOCS data. The LICF readings were recorded on the spot in the mill. (a) The DCO samples were also collected on the spot for AOCS measurement in the laboratory. (b) The correlation coefficient between the two measurements is 0.88.1 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |