| Electronic Components Datasheet Search |
|
QCL-LAB Datasheet(PDF) 5 Page - Wavelength Electronics, Inc. |
|
|
|||||||||||||||||||||||||||||
QCL-LAB Datasheet(HTML) 5 Page - Wavelength Electronics, Inc. |
|
5 / 24 page ![]() 5 SETUP INTERLOCKS The Wavelength Interlock Replacement Kit includes a male D-SUB with the passive interlock pins shorted and a BNC terminator. 1. For the passive interlock, on the back panel, short PIN 1 and PIN 2 on the QCL D-SUB. 2. For the active interlock, on the back panel, insert a BNC terminator in the ACTIVE LOCK BNC port. 3. On the front panel, the keyswitch must be on UNLOCK to enable the current to the QCL. TURN ON POWER 1. On the back panel, press the power switch to the |. The front panel power button light pulses slowly. 2. On the front panel, press the Power button. The button illuminates, the touchscreen activates, and the Control screen is active. 3. The front panel displays dashes instead of digits until the unit has finished its power-up sequence (~10 seconds). SET LIMITS 1. Press to access the Limit Screen. 2. On the Limit screen, press the blue Limit Current value and rotate the Adjustment knob to change to the desired value. The instrument will beep when set. NOTE: The Max Supply Voltage and Cable Resistance values can be ignored for now. ADJUST SETPOINT 1. Press to access the Control Screen. 2. Press the Setpoint current value and turn the Adjustment knob to change it. The instrument will beep when set. ENABLE CURRENT Press the ENABLE button. There is a standard 2-second delay before the button illuminates and the current flows. SHUTDOWN THE INSTRUMENT If the Enable button is illuminated, current is still flowing to the test load. Before shutting down, the current needs to be turned off. 1. Press the Enable button. The button light will turn off and current to the QCL test load will stop. 2. On the front panel, press the Power button. The touchscreen will go black but the button light slowly pulses blue to indicate that the back Power button is still on. NOTE: Turning off only the front Power button puts the instrument in Standby mode. 3. On the back panel, press the power switch to O. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |