ST10F280 Datasheet(HTML) 160 Page - STMicroelectronics |
|
160 / 239 page ![]() CAN modules ST10F280 160/239 Doc ID 8673 Rev. 3 Note: Reading the upper half of the Control Register (status partition) will clear the Status Change Interrupt value in the Interrupt Register, if it is pending. Use byte accesses to the lower half to avoid this. 15.4 CAN interrupt handling The on-chip CAN Module has one interrupt output, which is connected (through a synchronization stage) to a standard interrupt node in the ST10F280 in the same manner as all other interrupts of the standard on-chip peripherals. The control register for this interrupt is XP0IC (located at address F186h/C3h for CAN1 and F18Eh/C7h for CAN2 in the ESFR range). The associated interrupt vector is called XP0INT at location 100h (trap number 40h) and XP1INT at location 104h (trap number 41h). With this configuration, the user has all control options available for this interrupt, such as enabling/disabling, level and group priority, and interrupt or PEC service (see note below). LEC Last Error Code This field holds a code which indicates the type of the last error occurred on the CAN bus. If a message has been transferred (reception or transmission) without error, this field will be cleared. Code “7” is unused and may be written by the CPU to check for updates. 0: No Error 1: Stuff Error: More than 5 equal bit in a sequence have occurred in a part of a received message where this is not allowed. 2: Form Error: A fixed format part of a received frame has the wrong format. 3: AckError: The message this CAN controller transmitted was not acknowledged by another node 4: Bit1Error: During the transmission of a message (with the exception of the arbitration field), the device wanted to send a recessive level (“1”), but the monitored bus value was dominant 5: Bit0Error: During the transmission of a message (or acknowledge bit, active error flag, or overload flag), the device wanted to send a dominant level (“0”), but the monitored bus value was recessive. During busoff recovery this status is set each time a sequence of 11 recessive bit has been monitored. This enables the CPU to monitor the proceeding of the busoff recovery sequence (indicating the bus is not stuck at dominant or continuously disturbed). 6: CRCError: The CRC check sum was incorrect in the message received. TXOK Transmitted Message Successfully Indicates that a message has been transmitted successfully (error free and acknowledged by at least one other node), since this bit was last reset by the CPU (the CAN controller does not reset this bit!). RXOK Received Message Successfully Indicates that a message has been received successfully, since this bit was last reset by the CPU (the CAN controller does not reset this bit!). EWRN Error Warning Status Indicates that at least one of the error counters in the EML has reached the error warning limit of 96. BOFF Busoff Status Indicates when the CAN controller is in busoff state (see EML). |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |