14 / 32 page ![]() In some applications additional filtering may be useful to eliminate any jitter associated with the discrete current pulses from the phase detector. In this case a capacitor whose value is no more than 0.1 C can be placed across the RC filter net- work (C2 in Figure 5). Filter Design Example The following is a step by step example of how to derive the loop filter components. The CS5317 A/D sampling clock is to be derived from a 9600 Hz clock source. The application requires the sig- nal passband of the CS5317 to be 4 kHz. The on-chip digital filter of the CS5317 has a 3 dB passband of CLKOUT/488.65 (see Note 4 in the data sheet specifications tables). The 4 kHz pass- band requirement dictates that the sample clock (CLKOUT) of the CS5317 be a minimum of 4000 X 488.65 = 1.954 MHz. This requires the VCO to run at 3.908 MHz. The 3.908 MHz rate is 407 times greater than the 9600 Hz PLL input clock. Therefore the CS5317 must be set up in mode CLKG2 with N = 512. If the CLKG1 mode were used (N = 256), too narrow of a signal band- width through the A/D would result. Once the operating mode has been determined from the system requirements, a value for the damping factor must be chosen. Figure 6 illus- trates the dynamic aspects of the system with a given damping factor. Damping factor is gener- ally chosen to be between 0.5 and 2.0. The choice of 0.5 will result in an overshoot of 30 % to a step response whereas the choice of 2.0 will result in an overshoot of less than 5 %. For example pur- poses, let us use a damping factor of 1.0. So, let us begin with the following variables : Ko = - 10 Mradians/volt.sec Kd = - 8 µA/radian N = 512 ζ = 1.0 To calculate values for the resistor R and capaci- tor C of the filter, we must first derive a value for ωn. Using the general rule that the sample clock should be at least 20 times higher frequency than the 3dB bandwidth of the PLL control loop: CLKIN ≥ 20 ω 3dB where CLKIN = 9600 Hz = 2 π 9600 radians/sec. So: ω 3dB = 2π 9600/20 = 3016 radians/sec. Knowing ω 3dB and the damping factor of 1.0, we can calculate the natural frequency, ωn , of the control loop: ωn = ω3dB √ 2 ζ2 + 1 + √ (2ζ2 + 1)2 + 1 ωn = 3016 √ 2 (1)2 + 1 + √ (2(1)2 + 1)2 + 1 ωn = 1215 1 ⁄ sec Once the natural frequency, ωn , is determined, values for R and C for the loop filter can be cal- culated: R = 2 ζωnN/KoKd R = 2(1)(1215 1/s) 512/(-10Mrad/v.s.)(-8 µA/rad) R = 15552 v/A = 15.55 k Ω. Use R = 15 kΩ. C = KoKd/N ωn2 C = (-10 Mrad/v.s)(- 8 µA/rad)/512 (1215 1/s)2 C = 105.8 x 10 -9 A.s/v = 105 nF. Use 0.1 µF. The above example assumed typical values for Ko and Kd. Your application may require a worst case analysis which includes the minimum or maximum values. Table 2 shows some other ex- ample situations and R and C values. CS5317 14 DS27F4 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |