124 / 264 page ![]() Pre-drivers - ExtFET (MOS_Gate1/2/3/4/5) - PRD[1:5] L9788 124/264 DS12308 Rev 4 9.2 ON state diagnostic In the On state of pre-driver, the diagnosis will compare the Drain-source voltage with the threshold generated internal. If MOS_DRAIN_X>Vth_DS_XXX (PRDx_VDS[0:2] CONFIG_REG5/ CONFIG_REG6 / CONFIG_REG7)for a filter time, the Drain short to battery fault will be confirmed. The internal comparator reads the voltage on drain pin versus a dedicated GND sense pin (PIN X) that at application should be connected on the source of external mos. Starting from the condition ON state a programmable blanking time (MSC CONFIG_REG16=PRDx_BLK[1:0]) is applied to prevent the detection of the short-to- battery fault. The blanking time is not applied when the driver is already ON.The pre-driver will switch OFF and the fault will be latched until the Read_Diag_CMD action. This bit can be reset by every Read Diag Communication. To re-activate ON the power stage in this two following conditions: The MSC command still High, when the Fault OVC Bit is read by MSC communication. The MSC command becomes Low and then again High. When Bit MSC_O2HPredr_1 = 1 the VDS comparator of predriver 1 is ignored. When Bit MSC_O2HPredr_3 = 1 the VDS comparator of predriver 3 is ignored. When Bit MSC_O2HPredr = 1 the VDS comparator of predriver 2 (or 4) is enabled immediately with the turn ON command of Predriver (and checked by logic after the blanking time), while when Bit MSC_O2HPredr = 0 the VDS comparator of corresponding channel is enabled after selected blanking time. The over current protection can be done reading the voltage on external Rshunt using the VDS comparator of predriver 2&4. 9.3 ON/OFF state - Error in status diagnosis Refer to Section 7.1.3. 9.4 Error handling Table 53. Pre-driver - ExtFET error handling Type of error Detection condition Action Clear MSC flag Restart condition Driver diagnostic Overcurrent (OVC) Driver on Driver is put in off state. The fault is latched in MSC diagnosis register. On read At MSC read of diagnosis register if MSC command is still high. If MSC command is low and high again. Short to ground (STG) Driver off The fault is latched in MSC diagnosis register. On read |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |