6 / 263 page ![]() 6 2548E–AVR–07/06 ATmega406 2.2.10 Port C (PC0) Port C is a high voltage Open Drain output port. 2.2.11 Port D (PD1:PD0) Port D is a low-voltage 2-bit bi-directional I/O port with internal pull-up resistors (selected for each bit). As inputs, Port D pins that are externally pulled low will source current if the pull-up resistors are activated. The Port D pins are tri-stated when a reset condition becomes active, even if the clock is not running. Port D also serves the functions of various special features of the ATmega406 as listed in ”Alter- nate Functions of Port D” on page 72. 2.2.12 SCL SMBUS clock, Open Drain bidirectional pin. 2.2.13 SDA SMBUS data, Open Drain bidirectional pin. 2.2.14 OC/OD/OPC High voltage output to drive external Charge/Discharge/Pre-charge FETs. For details, see ”FET Control” on page 133. 2.2.15 PI/NI Unfiltered positive/negative input from external current sense resistor, used by the battery pro- tection circuit, for over-current and short-circuit detection. For details, see ”Battery Protection” on page 125. 2.2.16 PPI/NNI Filtered positive/negative input from external current sense resistor, used to by the Coulomb Counter ADC to measure charge/discharge currents flowing in the battery pack. For details, see ”Coulomb Counter - Dedicated Fuel Gauging Sigma-delta ADC” on page 106. 2.2.17 NV/PV1/PV2/PV3/PV4 NV, PV1, PV2, PV3, and PV4 are the inputs for battery cells 1, 2, 3 and 4, used by the Voltage ADC to measure each cell voltage. For details, see ”Voltage ADC – 10-channel General Pur- pose 12-bit Sigma-Delta ADC” on page 116. 2.2.18 PVT PVT defines the pull-up level for the OD output. 2.2.19 BATT Input for detecting when a charger is connected. This pin also defines the pull-up level for OC and OPC outputs. 2.2.20 RESET Reset input. A low level on this pin for longer than the minimum pulse length will generate a reset, even if the clock is not running. The minimum pulse length is given in Table 11 on page 38. Shorter pulses are not guaranteed to generate a reset. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |