| Electronic Components Datasheet Search |
|
HMPVIDEVAL/ISA Datasheet(PDF) 6 Page - Intersil Corporation |
|
|
|||||||||||||||||||||||||||||
HMPVIDEVAL/ISA Datasheet(HTML) 6 Page - Intersil Corporation |
|
6 / 45 page ![]() 6 FN4643.3 April 19, 2007 Input Signal Detection If no input video signal is detected for 16 consecutive line periods, nominal video timing is generated for the previously detected or programmed video standard. A maskable interrupt is provided for the condition of “Input Signal Loss” allowing the host to enable blue field output if desired. Vertical Sync and Field Detection The vertical sync and field detect circuit uses a low time counter to detect the vertical sync sequence in the video data stream. The low time counter accumulates the low time encountered during any sync pulse, including serration and equalization pulses. When the low time count exceeds the vertical sync detect threshold, VSYNC is asserted immediately. FIELD is asserted at the same time that VSYNC is asserted. FIELD is asserted low for odd fields and high for even fields. Field is determined from the location in the video line where VSYNC is detected. If VSYNC is detected in the first half of the line, the field is odd. If VSYNC is detected in the second half of a line, the field is even. In the case of lost vertical sync or excessive noise that would prevent the detection of vertical sync, the FIELD output will continue to toggle. Lost vertical sync is declared if after 337 lines, a vertical sync period was not detected for 1 or 3 (selectable) successive fields as specified by bit 2 of the GENLOCK CONTROL register 04H. When this occurs, the PLLs are initialized to the acquisition state. Y/C Separation A composite video signal has the luma (Y) and chroma (C) information mixed in the same video signal. The Y/C separation process is responsible for separating the composite video signal into these two components. The HMP8117 utilizes a comb filter to minimize the artifacts that are associated with the Y/C separation process. Input Sample Rate Converter The input sample rate converter is used to convert video data sampled at the CLK2 rate to a virtual 4xfSC sample rate for comb filtering and color demodulation. An interpolating filter is used to generate the 4xfSC samples as illustrated in Figure 2. Comb Filter A 2-line comb filter, using a single line delay, is used to perform part of the Y/C separation process. During S-video operation, the Y signal bypasses the comb filter; the C signal is processed by the comb filter since it is an integral part of the chroma demodulator. During PAL operation, the chroma trap filter should also be enabled for improved performance. Since a single line store is used, the chroma will normally have a half-line vertical offset from the luma data. This may be eliminated, vertically aligning the chroma and luma samples, at the expense of vertical resolution of the luma. Bit 0 of the OUTPUT FORMAT register 02H controls this option. Chroma Demodulation The output of the comb filter is further processed using a patented frequency domain transform to complete the Y/C separation and demodulate the chrominance. Demodulation is done at a virtual 4xfSC sample rate using the interpolated data samples to generate U and V data. The demodulation process decimates by 2 the U/V sample rate. Output Sample Rate Converter The output sample rate converter converts the Y, U and V data from a virtual 4xfSC sample rate to the desired output sample rate (i.e., 13.5MHz). It also vertically aligns the samples based on the horizontal sync information embedded in the digital video data stream. The output sample rate is determined by the input video standard and the selected rectangular/square pixel mode. The output pixel rate is 1/2 of the CLK2 input clock frequency. The output format is 4:2:2 for all modes except the RGB modes which use a 4:4:4 output format. CLK2 Input The decoder requires a stable clock source for the CLK2 input. For best performance, use termination resistor(s) to minimize pulse overshoot and reflections on the CLK2 input. Since chroma demodulation uses the virtual 4xfSC, any jitter on CLK2 will be transferred as chrominance error on the output pixels. The CLK2 clock frequency must be one of the valid selections from Table 1 below based on the video standard and desired pixel mode. The CLK2 should be derived from a stable clock source, such as a crystal. CLK2 must have at least a ±50ppm accuracy and at least a 60/40% duty cycle to ensure proper TIME INCOMING VIDEO SAMPLES TIME RESAMPLED VIDEO 4xfSC FIGURE 2. SAMPLE RATE CONVERSION TABLE 1. VIDEO STANDARD CLOCK RATE SELECTION SUMMARY VIDEO FORMAT VALID CLK2 FREQUENCIES (MHz) RECTANGULAR PIXEL MODE SQUARE PIXEL MODE (M) NTSC, (M) PAL 27.00 24.54 (B, D, G, H, I, N, NC) PAL 27.00 29.50 HMP8117 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |