92 / 109 page ![]() Common to F3SG-SR and F3SG-PG 92 Standard Muting Mode/Exit-Only Muting Mode with Intelligent Tap [Wiring Example] F3SG-SRA Available F3SG-PGA-A/-L Available F3SG-SRB Available F3SG-PGA-C Available *11 S1 S2 S3 *3 *8 F39-SGIT-IL3 24 VDC Wiring for NPN *1 24 VDC IO-Link Master *7 F39-JG B-L/ XS5F-D521-DJ0-IL F39-JG A-D F39-JGR3K-L and F39-JG □B-L F39-JGR3K-D and F39-JG □B-D IN PLC *4 IN1 Safety controller *5 *6 IN2 MUTE A MUTE B OSSD Timing chart Beam state: Unblocked Blocked S1: Lockout reset switch, override switch or override cancel switch S2, S3: Muting sensor PLC: Programmable logic controller (Used for monitoring only. NOT related to safety system.) Intelligent Tap Needed : Indicates a switch position. Function Setting DIP switch SD Manager 3 EDM *9 EDM Disabled [External device monitoring] : Disable Interlock *9 Auto Reset [Start interlock] : Disable [Restart interlock] : Disable Operating Range Selection *10 Long [Operating Range Selection] : Long mode Standard Muting Mode N/A [Muting] : Enable [Muting mode] : Standard Muting (Installation Example1/2) Exit-Only Muting Mode N/A [Muting] : Enable [Muting mode] : Exit-Only Muting Test Input N/A Wired Synchronization Connect the emitter and receiver with the Intelligent Tap. 3ON 4ON 5ON 8ON *1. Reverse the polarity of the power supply when using in the NPN system. Select a PLC and a safety controller of PNP or NPN type according to the system of your application. *2. Also used as OVERRIDE INPUT line. *3. Make sure to connect an override cancel switch to the RESET line when using the override function. Otherwise the override state may not be released by the override cancel switch, resulting in serious injury. *4. When connecting to the PLC, the output mode must be changed with the SD Manager 3 according to your application. For the setting this function, refer to the User's Manual (Man.No.Z405). *5. Refer to page 79 for more information. *6. The safety controller and the F3SG-SR/PG must share the power supply or be connected to the common terminal of the power supply. *7. For connecting with the IO-Link Master unit, refer to an instruction manual of the IO-Link Master unit you use. *8. This is the case for a PELV circuit. *9. Set the function with the DIP Switches on the Intelligent Tap or SD Manager 3. *10.Set the function with the DIP Switches on the Intelligent Tap or SD Manager 3 and wire according to the wiring diagram after restoring the settings to the FE3SG-SR/PG when the F3SG-SR/PG or F3SG-PGA-L is used in Short Mode. The F3SG-PGA-A/-C do not support the operating range selection function. *11.When wiring the emitter/receiver of the F3SG-PGA-C, follow the same wiring as for the receiver in the figure above. Wiring of the emitter side is not required. Note: 1. When using the Intelligent Tap (F39-SGIT-IL3), the following functions are not available. • External Test • Operating Range Selection by wiring • Optical Synchronization 2. For the functional earth connection, refer to page 83. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |